2020
DOI: 10.1016/j.medengphy.2020.08.005
|View full text |Cite|
|
Sign up to set email alerts
|

Characterizing loads at transfemoral osseointegrated implants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 54 publications
0
9
0
1
Order By: Relevance
“…Unfortunately, this hypothesis could only be partially validated with the current understanding of loading profile applied by BAP estimated using inverse dynamics or measured with a transducer (Dumas et al, 2009;Dumas et al, 2017;Frossard et al, 2011b;Harandi et al, 2020;Niswander et al, 2020;Thesleff et al, 2018). Lee et al (2007Lee et al ( , 2008 reported some loading characteristics during walking, ascending and descending ramp and stairs for a cohort of TFAs fitted screw-type implants and basic components (e.g., mechanically passive knees, multi-axial foot-ankle) (Frossard, 2019;Lee et al, 2007;Lee et al, 2008b).…”
Section: Current Knowledge Of Loading Profilementioning
confidence: 99%
See 1 more Smart Citation
“…Unfortunately, this hypothesis could only be partially validated with the current understanding of loading profile applied by BAP estimated using inverse dynamics or measured with a transducer (Dumas et al, 2009;Dumas et al, 2017;Frossard et al, 2011b;Harandi et al, 2020;Niswander et al, 2020;Thesleff et al, 2018). Lee et al (2007Lee et al ( , 2008 reported some loading characteristics during walking, ascending and descending ramp and stairs for a cohort of TFAs fitted screw-type implants and basic components (e.g., mechanically passive knees, multi-axial foot-ankle) (Frossard, 2019;Lee et al, 2007;Lee et al, 2008b).…”
Section: Current Knowledge Of Loading Profilementioning
confidence: 99%
“…To date, evidence confirming the alleged biomechanical advantages of state-of-the-art components are spares. Cleary, there is a need for a better understanding of loading profile applied by BAP fitted with stateof-the-art components during daily activities (Niswander et al, 2020).…”
Section: Need For Loading Profile With State-of-the-art Componentsmentioning
confidence: 99%
“… These datasets are essential for promoters of prosthetic care innovations (e.g., users, clinicians, engineers, scientists, administrators) because they provide valuable insights supporting the prescription of advanced prosthetic components to the growing population of individuals suffering from lower limb loss choosing bionics solutions [6] , [7] , [8] , [9] , [10] , [11] . The confounders of the loading information as well as the new evidence of inter-participants variability of loading patterns, loading boundaries and loading local extrema are required to inform providers of prosthetic care who will design subsequent cross-sectional and longitudinal studies (e.g., statistical planning, power calculation) as well as subsequent literature reviews and meta-analyzes [12] , [13] , [14] . More precisely, the loading datasets are critical to clinicians (e.g., rehabilitation specialists) and engineers (e.g., manufacturers of components) designing finite element models of prosthetic components and osseointegrated implants parts (e.g., medullar and percutaneous parts), algorithms capable to recognize the loading patterns applied on a residual limb during daily activities, as well as clinical trials testing effects of particular interventions (e.g., design-based selection of components, alignment of prostheses) [15] , [16] , [17] .…”
Section: Value Of the Datamentioning
confidence: 99%
“…The confounders of the loading information as well as the new evidence of inter-participants variability of loading patterns, loading boundaries and loading local extrema are required to inform providers of prosthetic care who will design subsequent cross-sectional and longitudinal studies (e.g., statistical planning, power calculation) as well as subsequent literature reviews and meta-analyzes [12] , [13] , [14] .…”
Section: Value Of the Datamentioning
confidence: 99%
“…Vibration transmissions of prostheses were investigated in a study by Haggstrom et al 9 The test leg prosthesis in their study was used without any loading, with vibratory stimulation of the prosthetic foot at fixed frequencies (8,16,32,64,125, and 250 Hz), followed by measurement of the vibrations at the foot and socket of the prosthesis.…”
Section: Introductionmentioning
confidence: 99%