Characterization of the evanescent field profile and bound mass sensitivity of a label-free silicon photonic microring resonator biosensing platform

Abstract: Silicon photonic microring resonators have emerged as a sensitive and highly multiplexed platform for real-time biomolecule detection. Herein, we profile the evanescent decay of device sensitivity towards molecular binding as a function of distance from the microring surface. By growing multilayers of electrostatically bound polymers extending from the sensor surface, we are able to empirically determine that the evanescent field intensity is characterized by a 1/e response decay distance of 63 nm. We then app… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
98
1

Year Published

2011
2011
2018
2018

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 103 publications
(103 citation statements)
references
References 44 publications
(57 reference statements)
4
98
1
Order By: Relevance
“…In practice, a measurement rate of 10 Hz is used. This is very fast compared to measurement rates described for other systems such as once per 8 s (5 MRRs [16], or 32 MRRs [14]) or once per minute (12 MRRs [21]). This measurement rate is sufficient enough to monitor drastic changes in refractive index, for example, when regeneration is carried out with high salt solutions.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In practice, a measurement rate of 10 Hz is used. This is very fast compared to measurement rates described for other systems such as once per 8 s (5 MRRs [16], or 32 MRRs [14]) or once per minute (12 MRRs [21]). This measurement rate is sufficient enough to monitor drastic changes in refractive index, for example, when regeneration is carried out with high salt solutions.…”
Section: Resultsmentioning
confidence: 99%
“…Fabrication of integrated MRRs has been described in the case of all three main IO main platforms, especially SOI [10,13,14] but also InP [15] and Si 3 N 4 [12,16,17] while realization was also reported for polymer systems [18,19]. The SOI platform offers a large refractive index contrast and therewith a small allowable bend radius and thus footprint.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…(4)(5)(6)(7)(8)(9)(10)(11) In addition, microring resonator (MRR)-based biosensors have also been intensively developed because of their compactness, high sensitivity, and low cost. (12)(13)(14)(15)(16)(17)(18)(19)(20) We have also proposed and developed a biosensor based on an MRR-loaded Mach-Zehnder interferometer (MRR-MZI) (21) that has a higher sensitivity than conventional MRR sensors. Although avidin at a concentration as low as 20 pM was detected as a change in light transmittance with the MRR-MZI sensor, a sufficient change in transmittance has not yet been obtained.…”
Section: Introductionmentioning
confidence: 99%
“…We take advantage of the successful micro-ring resonator platform that brought about various demonstrations of real-time sample analysis with concentration accuracies down to 10 ng mL −1 and as low as 60 fM when receptor molecules are used. 5,6 A micro-ring resonator is a resonant device in which the resonant optical frequencies depend on the refractive index of the surrounding fluid. The refractive index of the fluid alters with changing concentration of its solutes and their refractive indices.…”
Section: Introductionmentioning
confidence: 99%