Characterization of permselective coatings electrosynthesized on Pt–Ir from the three phenylenediamine isomers for biosensor applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

14
103
0
4

Year Published

2009
2009
2020
2020

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 77 publications
(121 citation statements)
references
References 90 publications
14
103
0
4
Order By: Relevance
“…There was no statistically significant trend in the P(H 2 O 2 )% data over the entire range of fiber lengths (linear regression R 2 ) 0.03). This is in line with expectation, because the high H 2 O 2 permeability in PPD is one of its outstanding qualities which makes this polymer (both ortho and meta forms) 56,83,94 the permselective membrane of choice in many first-generation biosensor designs. 17,78,81,85 Thus, the compromised structure of PPD deposited at the insulation edge, indicated by the analysis for P(AA)% above, would not be anticipated to impact on P(H 2 O 2 )% values already close to those for the bare metal.…”
Section: P(aa)% Analysis For Ppd-modified Electrodessupporting
confidence: 87%
“…There was no statistically significant trend in the P(H 2 O 2 )% data over the entire range of fiber lengths (linear regression R 2 ) 0.03). This is in line with expectation, because the high H 2 O 2 permeability in PPD is one of its outstanding qualities which makes this polymer (both ortho and meta forms) 56,83,94 the permselective membrane of choice in many first-generation biosensor designs. 17,78,81,85 Thus, the compromised structure of PPD deposited at the insulation edge, indicated by the analysis for P(AA)% above, would not be anticipated to impact on P(H 2 O 2 )% values already close to those for the bare metal.…”
Section: P(aa)% Analysis For Ppd-modified Electrodessupporting
confidence: 87%
“…1, top) shows that the integrity of the Teflon-metal seal was not compromised significantly by the cutting procedure used to form the bare disc from the wire. Interesting aspects of the surface structure of PPD formed from the different isomers of phenylenediamine [27][28][29][30] and other electro-deposited polymers [31][32][33] have been revealed in the past by scanning electron microscopy. Crater-like features described previously for PPD formed on metal cylinders from the ortho monomer [27,30] were also evident at higher magnifications for PPD electro-deposited onto the Pt D electrode ( Fig.…”
Section: Scanning Electron Microscopymentioning
confidence: 99%
“…PPD modified Pt electrodes are extensively utilised to improve selectivity of the polymer layer of both electrochemical sensors [6,17,[22][23][24] and biosensors [11,[25][26][27][28] since extracellular concentrations of certain metabolites are considered low in relation to the excessive concentration of AA. Therefore it is imperative that the integrity of the polymer is retained following implantation.…”
Section: Shelf-life Studies-effect Of Repeated Aa Calibrationsmentioning
confidence: 99%