Characterization of implant materials in fetal bovine serum and sodium sulfate by electrochemical impedance spectroscopy. I. Mechanically polished samples

Abstract: Electrochemical impedance spectroscopy is used to monitor the long-term stability (up to 150 days) of mechanically polished commercial pure titanium, Ti6Al4V, Ti6Al7Nb, and CoCrMo alloys in 0.1M sodium sulfate and fetal bovine serum. A capacitive spectrum in the frequency range from 10(-3) to 10(5) Hz is always found and the impedance spectra can be fitted by a simple parallel RC circuit with a constant phase element. The open circuit potential observed in serum is always more cathodic and the polarization res… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

15
123
2

Year Published

2003
2003
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 109 publications
(140 citation statements)
references
References 19 publications
15
123
2
Order By: Relevance
“…Hence, the total overlapping between the two time constants is entirely attributed to the decrease in the total and tips' capacitances caused by the formation of a compact adsorption layer of organic molecules onto the passive film. 7 The adsorption layer originates a capacitor in series with the film capacitance (Fig. 10) determining the decrease in the experimental values of the equivalent capacitances, as experimentally observed in Figure 7.…”
Section: Interaction Of Serum With Sandblasted Surfacesmentioning
confidence: 63%
See 4 more Smart Citations
“…Hence, the total overlapping between the two time constants is entirely attributed to the decrease in the total and tips' capacitances caused by the formation of a compact adsorption layer of organic molecules onto the passive film. 7 The adsorption layer originates a capacitor in series with the film capacitance (Fig. 10) determining the decrease in the experimental values of the equivalent capacitances, as experimentally observed in Figure 7.…”
Section: Interaction Of Serum With Sandblasted Surfacesmentioning
confidence: 63%
“…Mechanically polished samples show a specific polarization resistance between 8 and 20 M⍀ * cm 2 in sodium sulfate; in bovine serum values up to 40 M⍀ * cm 2 are reported 7 [ Fig. 11(a)].…”
Section: Effect Of the Surface Treatmentmentioning
confidence: 92%