2011
DOI: 10.1016/j.aca.2011.03.060
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of Hg(II) binding with different length phytochelatins using liquid chromatography and amperometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
13
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 30 publications
0
13
0
Order By: Relevance
“…The mobile phase consisted of 0.1% TFA in ultrapure filtered water pH = 2.00 and 0.1% TFA in acetonitrile. Separation was performed with gradient elution, as described in Dago et al 34 The electrochemical detector (ED), consisting of a flow cell (BAS, West Lafayette, IN, USA) and an Autolab PGSTAT-12 (Eco Chemie, Utrecht, The Netherlands), was coupled at the end of the column. The flow cell consisted of a glassy carbon working electrode (BAS) whose surface was polished daily, a stainless steel auxiliary electrode, and an Ag/AgCl (NaCl 3 mol L −1 ) reference electrode.…”
Section: Spe Procedures and Hplc-ed Analysis For The Determination Of...mentioning
confidence: 99%
“…The mobile phase consisted of 0.1% TFA in ultrapure filtered water pH = 2.00 and 0.1% TFA in acetonitrile. Separation was performed with gradient elution, as described in Dago et al 34 The electrochemical detector (ED), consisting of a flow cell (BAS, West Lafayette, IN, USA) and an Autolab PGSTAT-12 (Eco Chemie, Utrecht, The Netherlands), was coupled at the end of the column. The flow cell consisted of a glassy carbon working electrode (BAS) whose surface was polished daily, a stainless steel auxiliary electrode, and an Ag/AgCl (NaCl 3 mol L −1 ) reference electrode.…”
Section: Spe Procedures and Hplc-ed Analysis For The Determination Of...mentioning
confidence: 99%
“…These results suggested that the developed method for the determination of the six analytes was accurate and sensitive. Compared with other reported methods [27][28][29][30][31], similar response ranges but higher detection limits were achieved with the HPLC-ELSD method compared with the HPLC-fluorescence (Flu) method. However, the HPLC-Flu method has a complicated derivatization process, whereas low detection limits can be obtained with the HPLC-ELSD method relative to the HPLC-ED or ion-pair chromatography (IPC)-MS methods (table 2).…”
Section: Calibration Curves Linear Ranges and Detection Limitsmentioning
confidence: 68%
“…1% TFA in acetonitrile was used. Separation was performed with gradient elution, as described inDago et al, 2011. For the analysis of PC isoforms…”
mentioning
confidence: 99%