2000
DOI: 10.1063/1.1150466
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of geometrical detection-system properties for two-dimensional tomography

Abstract: Quantities that characterize the three-dimensional geometrical properties of detection systems for two-dimensional tomography are reviewed and compared. It is discussed how the quantities can be calculated and how they can be measured, including a measuring technique that uses a parallel laser beam. In many detection systems the finite detector size and the finite sizes of bounding apertures are not negligible, and these result in instrument functions with finite widths. Line-integral measurements are referred… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
20
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 17 publications
(21 citation statements)
references
References 16 publications
1
20
0
Order By: Relevance
“…Neglecting reflections one gets in poloidal direction, similar to the results given in [5] for pin-hole cameras:…”
Section: Transmission Function Of the Prototype Collimatorsupporting
confidence: 63%
See 2 more Smart Citations
“…Neglecting reflections one gets in poloidal direction, similar to the results given in [5] for pin-hole cameras:…”
Section: Transmission Function Of the Prototype Collimatorsupporting
confidence: 63%
“…For the next measurements a coating of the collimator channels will be tried to investigate by how much the reflections can be reduced. Using threaded holes as proposed in [5] will not be feasible for ITER due to the much smaller dimensions of the collimator channels required. Figure 4 gives a detailed overview of the measured and calculated transmission for channel 3.…”
Section: Transmission Function Of the Prototype Collimatormentioning
confidence: 99%
See 1 more Smart Citation
“…The method used for the assessment of the LOS characteristic of the ITER bolometer diagnostic components is based on previous work performed at JET [2]. It is currently under development for the utilization as a LOS calibration device in ASDEX Upgrade, the viability of the proposed method was shown previously [1].…”
Section: Experimental Set-upmentioning
confidence: 99%
“…The tool was once developed for the measurement and assessment of the ITER bolometer diagnostic [7] and is based on work conducted at JET [12] [13]. Experience to analyse and evaluate the results were gained during the collimator development for ITER [14].…”
Section: Experimental Set-upmentioning
confidence: 99%