Characterization of embeddable potentiometric thick-film sensors for monitoring chloride penetration in concrete

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
33
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(33 citation statements)
references
References 31 publications
(21 reference statements)
0
33
0
Order By: Relevance
“…e interference of hydroxide ions would determine an OCP response, not proportional to the activity of chloride ions only. Hence, the sensor's OCP is associated with the ratio of chloride to hydroxide ions at the sensor's surface [6,[9][10][11][12][13][14]. In such cases, the measured OCP does not only present the Ag/AgCl equilibrium (3) but also reflects a mixed potential described by the Ag/AgCl/Ag 2 O equilibrium (4).…”
Section: Introductionmentioning
confidence: 99%
“…e interference of hydroxide ions would determine an OCP response, not proportional to the activity of chloride ions only. Hence, the sensor's OCP is associated with the ratio of chloride to hydroxide ions at the sensor's surface [6,[9][10][11][12][13][14]. In such cases, the measured OCP does not only present the Ag/AgCl equilibrium (3) but also reflects a mixed potential described by the Ag/AgCl/Ag 2 O equilibrium (4).…”
Section: Introductionmentioning
confidence: 99%
“…Several publications using electrochemical embedded sensors to monitor corrosion of RCS [46,73,[78][79][80][81][82][83][84][85][86][87][88][89][90] including sensors with wireless communication of data [51,[91][92][93][94][95] have been found. In 2009, Martínez and Andrade [88], published a paper where several examples of recorded data for corrosion potential, electrical resistance and corrosion rates were presented.…”
Section: Corrosion Assessment With Electrochemical Sensorsmentioning
confidence: 99%
“…It s necessary to take into consideration the processing and presentation of the data together with the durability of the sensor itself. Nowadays, embedded sensors are used to measure the following parameters: chloride content [75,78,86,95], pH [106,107], moisture [108,109], i corr [46,73,80,81,88], temperature [93,108,110], potential [89,91], ρ [43,[111][112][113], oxygen transport [72,78] and i gal [82,90].…”
Section: Corrosion Assessment With Electrochemical Sensorsmentioning
confidence: 99%
“…The equations that relate the effect of an interferent on the electrode potential have been developed in a previous work [34]. Equation 6 deals with the case of the interference of chloride ions.…”
Section: 15chloride Interferencementioning
confidence: 99%