Characterization of continuous wave ultrasound for acousto-optic modulated diffuse correlation spectroscopy (AOM-DCS)

Abstract: Intra and post-operative blood flow monitoring of tissue has been shown to be effective in the improvement of patient outcomes. Diffuse correlation spectroscopy (DCS) has been shown to be effective in measuring blood flow at the bedside, and is a useful technique in measuring cerebral blood flow (CBF) in many clinical settings. However, DCS suffers from reduced sensitivity to blood flow changes at larger tissue depths, making measurements of CBF in adults difficult. This issue can be addressed with acousto-opt… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 30 publications
0
7
0
Order By: Relevance
“…47 Although achieving an adequate SNR at source-detector distances beyond 2.5 cm is challenging, recent studies have demonstrated promising new strategies to boost brain sensitivity. [48][49][50][51][52][53][54][55][56][57][58][59][60][61] Previous studies that used a 2L approach for DCS analysis assumed homogeneous or fixed optical properties from the literature. 12,15,17,20,21,26 This approach has the advantage of simplicity.…”
Section: Discussionmentioning
confidence: 99%
“…47 Although achieving an adequate SNR at source-detector distances beyond 2.5 cm is challenging, recent studies have demonstrated promising new strategies to boost brain sensitivity. [48][49][50][51][52][53][54][55][56][57][58][59][60][61] Previous studies that used a 2L approach for DCS analysis assumed homogeneous or fixed optical properties from the literature. 12,15,17,20,21,26 This approach has the advantage of simplicity.…”
Section: Discussionmentioning
confidence: 99%
“…These include time-of-flight selection (time-resolved/time-domain DCS 54 and the related iNIRS technique 55 ), pathlength selection through coherence gating, 56 and acoustic (ultrasound) tagging. 57 , 58 A major advantage of these techniques is that large source-detector separations are no longer needed, enabling compact probe design and/or dense spatial sampling and increased resolution, for example, for functional brain imaging. Further, time-domain DCS and iNIRS intrinsically sample the optical properties of the sample as well, providing both spectroscopic and flow property measurement.…”
Section: Directions Of Technical Developmentmentioning
confidence: 99%
“…These benefits include improved monitoring of cerebrovascular autoregulation dynamics, more robust identification of motion artefacts, and increased measurement throughput that could enable high spatial resolution with fewer detectors. Improvements in SNR are also motivated by the ability to perform flow measurements with improved spatial resolution and depth penetration through the use of acousto-optic tomography (AOT) [3,[8][9][10], which is an emerging hybrid imaging modality that makes use of the ultrasound modulation of light [11]. The modulation efficiency of photons by ultrasound is low at biologically safe power levels, and therefore significantly improved SNR is required in order to detect this modulated component [9].…”
Section: Motivationmentioning
confidence: 99%