2018
DOI: 10.1016/j.polymertesting.2018.02.017
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of broad molecular weight distribution polyethylene with multi-detection gel permeation chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…If the PDI value is close to 1, it indicates that the molecular weight distribution of the substance is narrow. If the PDI value is ≥ 2, it indicates that the molecular weight distribution of the substance is broad (Cheng et al, 2018). The PDI value of HA extracted from sludge in this paper was 2.0879, which indicated that the molecular weight distribution of HA was wide.…”
Section: Analysis Of Gpcmentioning
confidence: 70%
“…If the PDI value is close to 1, it indicates that the molecular weight distribution of the substance is narrow. If the PDI value is ≥ 2, it indicates that the molecular weight distribution of the substance is broad (Cheng et al, 2018). The PDI value of HA extracted from sludge in this paper was 2.0879, which indicated that the molecular weight distribution of HA was wide.…”
Section: Analysis Of Gpcmentioning
confidence: 70%
“…20 Here, we demonstrate the importance of measuring the refractive index increment, dn/dc, to measure the amount of polymer exiting the columns and thereby identify whether any material is lost during the measurement. 21 Furthermore, we show that PS swells more than some conjugated polymers in the carrier solvent, chlorobenzene, 22 and leads to a fortuitous agreement between accurate molecular weights and PS-relative calibrations. As such, this work proposes an explanation of the intermittent success of molecular weight determination of conjugated polymers from GPC using PS standards while also establishing procedures for extracting absolute molecular weights using a universal calibration.…”
Section: ■ Introductionmentioning
confidence: 66%
“…Here, we demonstrate the importance of measuring the refractive index increment, d n /d c , to measure the amount of polymer exiting the columns and thereby identify whether any material is lost during the measurement . Furthermore, we show that PS swells more than some conjugated polymers in the carrier solvent, chlorobenzene, and leads to a fortuitous agreement between accurate molecular weights and PS-relative calibrations.…”
Section: Introductionmentioning
confidence: 72%
“…Molecular weight (MW) distribution in the leachate was determined by gel permeation chromatography (SHIMADZU, LC-10ADVP). MW is analyzed according to previous literature [17].…”
Section: Methodsmentioning
confidence: 99%