Characterization of Atrial Propagation Patterns and Fibrotic Substrate With a Modified Omnipolar Electrogram Strategy in Multi-Electrode Arrays

Abstract: Introduction: The omnipolar electrogram method was recently proposed to try to generate orientation-independent electrograms. It estimates the electric field from the bipolar electrograms of a clique, under the assumption of locally plane and homogeneous propagation. The local electric field evolution over time describes a loop trajectory from which omnipolar signals in the propagation direction, substrate and propagation features, are derived. In this work, we propose substrate and conduction velocity mapping… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
15
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(17 citation statements)
references
References 31 publications
1
15
0
Order By: Relevance
“…Since the CV from omnipolar analysis is obtained from a ratio of signals, it does not necessitate specific activation times [7]. In [56], the technique is modified to estimate the omnipolar electrogram after inter-electrogram alignment within each clique to reduce the residual angular dependency of the classical omnipolar electrogram. In addition, [56] use the ratio of standard deviations = ([ φ] SD ∕[E a ] SD ) ̂ rather than peak-to-peak amplitudes, with the aim of reducing the effects of noise on the estimate.…”
Section: Electric Field From Omnipolar Signalsmentioning
confidence: 99%
“…Since the CV from omnipolar analysis is obtained from a ratio of signals, it does not necessitate specific activation times [7]. In [56], the technique is modified to estimate the omnipolar electrogram after inter-electrogram alignment within each clique to reduce the residual angular dependency of the classical omnipolar electrogram. In addition, [56] use the ratio of standard deviations = ([ φ] SD ∕[E a ] SD ) ̂ rather than peak-to-peak amplitudes, with the aim of reducing the effects of noise on the estimate.…”
Section: Electric Field From Omnipolar Signalsmentioning
confidence: 99%
“…Simulated signals were corrupted with noise excerpts obtained from real u-EGMs, as previously done in [8]. Two thousand different noise segments were extracted from u-EGMs recorded with a multi-electrode PentaRay ® catheter (Biosense-Webster, Inc., Diamond Bar, CA, USA) at intervals with no recorded EGMs.…”
Section: Synthetic Signalsmentioning
confidence: 99%
“…At each catheter position, u-EGMs were considered in the following five four-electrode cliques, according to the pole numbering in Fig. 4: (3,4,7,8), (7,8,11,12), (11,12,15,16), (15,16,19,20), (19,20,3,4) and the five-electrode clique (4,8,12,16,20), for their smaller inter-electrode spacing. As example, cliques (3,4,7,8) and (4,8,12,16,20) are depicted in Fig.…”
Section: Clinical Datamentioning
confidence: 99%
See 2 more Smart Citations