Characterization and performance of monolithic detector blocks with a dedicated ASIC front-end readout for PET imaging of the human brain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 2 publications
0
7
0
1
Order By: Relevance
“…Results show a very good linear performance (R=0.99999) of this chip and energy resolutions at the 511 keV peak as good as 12.2% FWHM, which are better than the VATA240 results which showed energy resolutions of 13.2% FWHM [3]. On the right of figure 3 we can also observe the good correlation between the energies deposited on the detector blocks with a PET coincidence trigger.…”
Section: Operation With Monolithic Detector Blocksmentioning
confidence: 58%
See 3 more Smart Citations
“…Results show a very good linear performance (R=0.99999) of this chip and energy resolutions at the 511 keV peak as good as 12.2% FWHM, which are better than the VATA240 results which showed energy resolutions of 13.2% FWHM [3]. On the right of figure 3 we can also observe the good correlation between the energies deposited on the detector blocks with a PET coincidence trigger.…”
Section: Operation With Monolithic Detector Blocksmentioning
confidence: 58%
“…We have evaluated the energy resolution of our detectors with VATA241 chip readout by acquiring spectra of 22 Na and 137 Cs radioactive sources. Results show a very good linear performance (R=0.99999) of this chip and energy resolutions at the 511 keV peak as good as 12.2% FWHM, which are better than the VATA240 results which showed energy resolutions of 13.2% FWHM [3].…”
Section: Operation With Monolithic Detector Blocksmentioning
confidence: 68%
See 2 more Smart Citations
“…Στην κατεύθυνση της κατασκευής μικρών και ευέλικτων συστημάτων απόκτησης δεδομένων αρκετές ομάδες αντικατέστησαν μέρος των αναλογικών ηλεκτρονικών με ψηφιακά ολοκληρωμένα κυκλώματα ειδικού σκοπού (Application Specific Integrated Circuit -ASIC). Συνήθως το συνολικό σύστημα περιλαμβάνει και ένα FPGA για τον έλεγχο των αναλογικών μερών αλλά και για επεξεργασία των σημάτων [70,71,72,73]. Ενώ τα συ-Κεφάλαιο 3.…”