2017
DOI: 10.1109/tpwrd.2016.2600277
|View full text |Cite
|
Sign up to set email alerts
|

Characteristics of Electromagnetic Disturbance for Intelligent Component Due to Switching Operations via a 1100 kV AC GIS Test Circuit

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(10 citation statements)
references
References 17 publications
0
9
0
Order By: Relevance
“…Digital Object Identifier 10.1109/TEMC.2023.3245206 countermeasures have been studied through measurements in actual substations or test platforms (e.g., [2], [3], [4], [5], [6], [7], [8], and [9]). On the other hand, numerical simulations are also practical tools for predicting electromagnetic transient phenomena and evaluating the effectiveness of countermeasures.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Digital Object Identifier 10.1109/TEMC.2023.3245206 countermeasures have been studied through measurements in actual substations or test platforms (e.g., [2], [3], [4], [5], [6], [7], [8], and [9]). On the other hand, numerical simulations are also practical tools for predicting electromagnetic transient phenomena and evaluating the effectiveness of countermeasures.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, numerical simulations are also practical tools for predicting electromagnetic transient phenomena and evaluating the effectiveness of countermeasures. Traditionally, circuit-theory-or transmission-line (TL)-theory-based simulation techniques have been studied for the electromagnetic transient analysis of secondary circuits [7], [8], [9], [10], [11], [12], [13], [14], [15], and simulation techniques for modeling high-frequency voltage and current transformers (VT and CT, respectively) have been proposed based on circuit elements and the use of the black-box technique [16], [17], [18], [19].…”
Section: Introductionmentioning
confidence: 99%
“…The result of the measurement, which was done by Hengtian WU and others, on the sensor ports in the 1100 kV GIS tested circuit showed the maximum disturbance voltage of intelligent component ports on the sensor exceeded 7 kV. The distribution of the main frequency of disturbance voltage of these ports concentrated on three frequency points of 5, 10 and 20 MHz [12]. Subject to the restriction of field conditions of the substations in question, however, only a small number of measurement samples are obtained in the above studies.…”
Section: Introductionmentioning
confidence: 99%
“…Compared with the traditional air insulated switchgear (AIS) substations, gas insulated switchgear (GIS) substations have many advantages such as less occupied space, safe operation, and easy maintenance. In order to improve the intelligence level of GIS substations, intelligent electronic devices (IEDs) are being extensively applied in GIS substations [1,2]. The electronic transformer is one part of IEDs, and it is the most critical metering device in GIS substations.…”
Section: Introductionmentioning
confidence: 99%