2021
DOI: 10.1016/j.ndteint.2021.102413
|View full text |Cite
|
Sign up to set email alerts
|

Characterisation of small embedded two-dimensional defects using multi-view Total Focusing Method imaging algorithm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 29 publications
0
6
0
Order By: Relevance
“…On the other hand, the use of the different modes has been extensively examined in PA imaging with piezoelectric array transducers. 13,[43][44][45][61][62][63][64] For example, multi-mode PLUS can utilize the shear-wave incidence. By making a wedge with an angle between the first and second critical angles for the piezoelectric transmitter, only the shear wave incidence can be performed.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…On the other hand, the use of the different modes has been extensively examined in PA imaging with piezoelectric array transducers. 13,[43][44][45][61][62][63][64] For example, multi-mode PLUS can utilize the shear-wave incidence. By making a wedge with an angle between the first and second critical angles for the piezoelectric transmitter, only the shear wave incidence can be performed.…”
Section: Discussionmentioning
confidence: 99%
“…Importantly, the scattering phenomena can accompany the mode conversion of the ultrasonic wave. 34,[42][43][44][45] When an incident wave is a longitudinal mode, the scattered waves contain not only a longitudinal mode but also a mode-converted shear mode. An LDV receives the longitudinal and modeconverted shear scattered waves at a point on the top surface.…”
Section: Multi-mode Plusmentioning
confidence: 99%
See 1 more Smart Citation
“…The delay-and-sum (DAS) beamforming is the most common method for TFM image reconstruction. DAS has the character of easy expansion and good secondary development because it can reconstruct the individual amplitude imaging slice of each emit-receiving channel signal in the region of interest [8,9]. For example, some adaptive weighting factors for improving the TFM imaging quality, such as coherence factor (CF), sign coherence factor (SCF), and vector coherence factor (VCF) [10][11][12][13], are proposed when the individual amplitude imaging slices are considered the statistical sample.…”
Section: Introductionmentioning
confidence: 99%
“…Ultrasonic arrays have been increasingly used for non-destructive evaluation (NDE) in recent years [1]. The adoption of the Full Matrix Capture (FMC) array data acquisition technique [2] resulted in the development of many post-processing algorithms [3][4][5][6][7][8][9], which provided improved array image quality and more accurate defect characterization [10][11][12][13][14][15][16]. Mathematical models of array data serve as a basis for developing and optimizing array image and defect characterization.…”
Section: Introductionmentioning
confidence: 99%