2021
DOI: 10.1016/j.chroma.2021.462022
|View full text |Cite
|
Sign up to set email alerts
|

Characterisation of selenium and tellurium nanoparticles produced by Aureobasidium pullulans using a multi-method approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(14 citation statements)
references
References 62 publications
1
10
0
Order By: Relevance
“…4 c). This phenomenon is also reported by 56 , which confirms the fact that when NPs tend to accumulate, DLS is not an accurate test for measuring the size of NPs. The composition of the black nanoparticles was verified to be elemental Te based on EDS data (Fig.…”
Section: Resultssupporting
confidence: 71%
See 2 more Smart Citations
“…4 c). This phenomenon is also reported by 56 , which confirms the fact that when NPs tend to accumulate, DLS is not an accurate test for measuring the size of NPs. The composition of the black nanoparticles was verified to be elemental Te based on EDS data (Fig.…”
Section: Resultssupporting
confidence: 71%
“…4 b). Based on DLS results, the obtained TeNPs of this study were smaller than those generated by Aureobasidium pullulans 56 , Aspergillus welwitschiae 57 and Ochrobactrum sp. 58 .…”
Section: Resultsmentioning
confidence: 70%
See 1 more Smart Citation
“…Conventional chemical analysis of precipitates and inclusions has been performed for various steel samples; however, the precipitates and inclusions are dissolved by acids 5) or alkalis, resulting in the loss of their size information. Meanwhile, asymmetric flow field-flow fractionation (AF4), which is a size-based separation technique, was used to analyze various nanoparticles [6][7][8] and steels. [9][10][11] AF4 does not require chromatographic support and can achieve size-dependent separation.…”
Section: Quantification Of Nanoparticles Via Flow Injection Analysis ...mentioning
confidence: 99%
“…16 Several techniques have been recently used for the characterization of SeNPs; their choice is driven by the properties to be determined. One of the most popular strategies is the on-line and off-line hyphenation of ICP-MS with separation techniques, such as high performance liquid chromatography (HPLC) [14][15][16][17][19][20][21] or asymmetric ow eld ow fractionation (AF4), 14,22,23 allowing in some cases the separation of soluble chemical species and different-size NPs. 24,25 Multiple detectors, such as dynamic light scattering (DLS), 22,23 multiangle light scattering (MALS) 23 or UV-VIS spectrophotometry 14,23 are used to conrm the presence of NPs.…”
Section: Introductionmentioning
confidence: 99%