2015
DOI: 10.1016/j.ejmp.2015.08.006
|View full text |Cite
|
Sign up to set email alerts
|

Characterisation of grids of point detectors in maximum skin dose measurement in fluoroscopically-guided interventional procedures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
16
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(17 citation statements)
references
References 12 publications
1
16
0
Order By: Relevance
“…The work of SG2 is dedicated to patient dosimetry for interventional procedures in cardiology and radiology, as well as dosimetry in cone beam computed tomography (CBCT) imaging. As the number and complexity of interventional cardiology (IC) procedures have been growing steadily, it has become crucial to provide patient-specific skin dose estimates during IC procedures (Dabin et al., 2015; Farah et al., 2015). The aim of this research is to foster the harmonisation of a radiation dose structured report, and to validate skin dose calculation software (by acceptance testing and developing quality control protocols) in IC, which will help to develop patient-specific dosimetry and optimise radiation protection.…”
Section: Eurados Scientific Work Programmementioning
confidence: 99%
“…The work of SG2 is dedicated to patient dosimetry for interventional procedures in cardiology and radiology, as well as dosimetry in cone beam computed tomography (CBCT) imaging. As the number and complexity of interventional cardiology (IC) procedures have been growing steadily, it has become crucial to provide patient-specific skin dose estimates during IC procedures (Dabin et al., 2015; Farah et al., 2015). The aim of this research is to foster the harmonisation of a radiation dose structured report, and to validate skin dose calculation software (by acceptance testing and developing quality control protocols) in IC, which will help to develop patient-specific dosimetry and optimise radiation protection.…”
Section: Eurados Scientific Work Programmementioning
confidence: 99%
“…TLD measurements were done with a uniform grid size of 140 × 40 cm 2 (86 TLDs in total and 5.7 cm inter-chip spacing). This grid spacing was selected based on results of Dabin et al [16], as a balance between spatial resolution and dosimeter preparation workload. TLDs were read according to participants own routine procedures.…”
Section: Maximum Skin Dose Measurementmentioning
confidence: 99%
“…The MSD value was estimated from the highest chip record. In order to take into account the median underestimation of MSD due to the finite grid spacing, the MSD value was corrected based on results of Dabin et al [16]. In that study, the authors used film measurements and numerical simulations of TACE, PCI and NE procedures to evaluate the MSD underestimation associated with the use of TLD grids.…”
Section: Maximum Skin Dose Measurementmentioning
confidence: 99%
See 2 more Smart Citations