2001
DOI: 10.1016/s0022-0728(01)00649-0
|View full text |Cite
|
Sign up to set email alerts
|

Characterisation of gold electrodes modified with self-assembled monolayers of l-cysteine for the adsorptive stripping analysis of copper

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

10
155
0
3

Year Published

2007
2007
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 264 publications
(168 citation statements)
references
References 35 publications
10
155
0
3
Order By: Relevance
“…As stated in a previous report [24], this behaviour is indicative of electrosorption process [34], [35] and [36], which suggests π-π interaction between the benzene rings of the phthalocyanine and the sidewalls of the immobilised SWCNT at the BPPGE. We also observed electropolymerization process (i.e., growth in anodic and cathodic peaks during our experiments) (not shown) but only when CoTAPc was still dissolving in DMF.…”
Section: Characterization Of Swcnt-cotapcsupporting
confidence: 80%
See 1 more Smart Citation
“…As stated in a previous report [24], this behaviour is indicative of electrosorption process [34], [35] and [36], which suggests π-π interaction between the benzene rings of the phthalocyanine and the sidewalls of the immobilised SWCNT at the BPPGE. We also observed electropolymerization process (i.e., growth in anodic and cathodic peaks during our experiments) (not shown) but only when CoTAPc was still dissolving in DMF.…”
Section: Characterization Of Swcnt-cotapcsupporting
confidence: 80%
“…7 and Fig. 8) are typical of CNT-based electrodes for thiols and related analytes [23] and [35]. Based on such reports, we ascribe the first oxidation peak (example in Fig.…”
Section: Electrochemical Impedance Spectroscopic Investigationsmentioning
confidence: 68%
“…As shown in Figure 2, the L-cysteine modified electrode exhibited two reduction peaks of cyclic voltammogram in 0.5 mol L À1 KOH solution. The first peak at about À0.7 V was due to the cleavage of the AuÀS bond, the second peak at about À1 V possibly due to a similar field-induced rearrangement of cysteine clusters after cleavage [16]. The reduction peaks were obtained by CV after self-assembly, demonstrating that L-cysteine had successfully assembled on electrode surface.…”
Section: Self-assembly Of L-cysteine and Characterizationmentioning
confidence: 87%
“…The modification of L-cysteine was by self-assembly [16]. The AuNPs-RGO composite modified GCE was immersed in 10 mmol L À1 L-cysteine solution.…”
Section: Fabrication Of the Sensormentioning
confidence: 99%
See 1 more Smart Citation