2020
DOI: 10.1080/13621718.2020.1794652
|View full text |Cite
|
Sign up to set email alerts
|

Characterisation of figure-eight shaped oscillation laser welding behaviour of 5083 aluminium alloy

Abstract: Figure-eight shaped oscillation movement of laser was studied to improve the welding quality of 5-mm-thick 5083 aluminium alloy. The tests were conducted at 3 kW laser power for frequency levels ranging from 25 to 125 Hz and focal point positions as 0, −1 and −2 mm. The quality of welds was characterised by non-destructive testing methods including visual, liquid penetrant and radiographic inspections. In addition, mechanical properties were determined by tensile tests and microstructures were examined by digi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
3
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 25 publications
1
3
2
Order By: Relevance
“…Using a narrower figure with the intention to produce a narrower weld in order to provide less space for pores to be formed did not prove to be effective. This finding is contradictory to the ones reported by Chen et al [ 14 ]: in their study, the narrowest amplitude (0.7 mm) also had the lowest porosity (14%). However, the narrowest amplitude from Chen et al [ 14 ] was 1.5 larger than the standard amplitude of 0.45 mm used in this study.…”
Section: Discussioncontrasting
confidence: 99%
See 4 more Smart Citations
“…Using a narrower figure with the intention to produce a narrower weld in order to provide less space for pores to be formed did not prove to be effective. This finding is contradictory to the ones reported by Chen et al [ 14 ]: in their study, the narrowest amplitude (0.7 mm) also had the lowest porosity (14%). However, the narrowest amplitude from Chen et al [ 14 ] was 1.5 larger than the standard amplitude of 0.45 mm used in this study.…”
Section: Discussioncontrasting
confidence: 99%
“…This finding is contradictory to the ones reported by Chen et al [ 14 ]: in their study, the narrowest amplitude (0.7 mm) also had the lowest porosity (14%). However, the narrowest amplitude from Chen et al [ 14 ] was 1.5 larger than the standard amplitude of 0.45 mm used in this study. In the aforementioned studies, welds with different parameters and beam oscillations were investigated, but this was limited to one weld per parameter set, which was never longer than 200 mm.…”
Section: Discussioncontrasting
confidence: 99%
See 3 more Smart Citations