2018
DOI: 10.1039/9781788010504-00001
|View full text |Cite
|
Sign up to set email alerts
|

Chapter 1. Practical Approaches for In Situ X-ray Crystallography: from High-throughput Screening to Serial Data Collection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 76 publications
0
2
0
Order By: Relevance
“…Although the traditional LCP sandwich glass plate enables high throughput screening of crystallization conditions, the glass sandwich plate cannot be used directly for X-ray diffraction screening due to poor X-ray transparency and strong scattering. Therefore, other materials have been explored to lower X-ray background scattering and increase transmission (43). Thin plastic polymers have been tested including polydimethylsiloxane (PDMS, 14-45 µm), polyvinyl chloride (PVC, 50 µm), polyethylene terephthalate (PET, 50 µm) and cyclic olefin copolymer (COC, 50-100 µm), and applications have been reported in microfluidic devices for on-chip characterization (44)(45)(46) and for the data collection on MPs (47,48).…”
Section: Imisx Platementioning
confidence: 99%
“…Although the traditional LCP sandwich glass plate enables high throughput screening of crystallization conditions, the glass sandwich plate cannot be used directly for X-ray diffraction screening due to poor X-ray transparency and strong scattering. Therefore, other materials have been explored to lower X-ray background scattering and increase transmission (43). Thin plastic polymers have been tested including polydimethylsiloxane (PDMS, 14-45 µm), polyvinyl chloride (PVC, 50 µm), polyethylene terephthalate (PET, 50 µm) and cyclic olefin copolymer (COC, 50-100 µm), and applications have been reported in microfluidic devices for on-chip characterization (44)(45)(46) and for the data collection on MPs (47,48).…”
Section: Imisx Platementioning
confidence: 99%
“…The original design and implementation of the beamline have been previously described (Sanchez-Weatherby et al, 2019) together with examples of initial data measured from thaumatin crystals in situ within crystallization plates. Subsequently, other beamlines have been developed with similar features (Okumura et al, 2022;Martiel et al, 2018) in parallel with microfluidic and serial crystallographic approaches (Martiel et al, 2019(Martiel et al, , 2018. Here, we describe the current status of the protein crystallization facility (PXF) and VMXi, and provide representative use cases, indicating the benefits of a highly automated RT datacollection pipeline.…”
Section: Introductionmentioning