2010
DOI: 10.1504/ijpec.2010.037629
|View full text |Cite
|
Sign up to set email alerts
|

Chaotic behaviour analysis in induction motors with scalar drive systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
11
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 9 publications
0
11
0
Order By: Relevance
“…The analysis of the chaos behavior in the closed-loop drive system of IM is performed using Poincaré mapping and linearization tools. 10 This paper shows that, unlike previous studies, chaotic behavior in this drive system occurs assuming the inverter is ideal, in closed-loop and open-loop systems. Also, unstable areas on the voltage-frequency plane change between closed-and open-loop systems.…”
mentioning
confidence: 61%
See 2 more Smart Citations
“…The analysis of the chaos behavior in the closed-loop drive system of IM is performed using Poincaré mapping and linearization tools. 10 This paper shows that, unlike previous studies, chaotic behavior in this drive system occurs assuming the inverter is ideal, in closed-loop and open-loop systems. Also, unstable areas on the voltage-frequency plane change between closed-and open-loop systems.…”
mentioning
confidence: 61%
“…In Reference 9, this open‐loop system uses a voltage‐to‐frequency scalar control to adjust the speed, in the presence of constant and periodic load. The analysis of the chaos behavior in the closed‐loop drive system of IM is performed using Poincaré mapping and linearization tools 10 . This paper shows that, unlike previous studies, chaotic behavior in this drive system occurs assuming the inverter is ideal, in closed‐loop and open‐loop systems.…”
Section: Introductionmentioning
confidence: 87%
See 1 more Smart Citation
“…Khatir et al in [21] modeled the B2B converter based on state equations and its dynamic performance during symmetric/non-symmetric faults, and step changes in the active and reactive are investigated. In [22][23][24] scalar and vector drive control systems are elaborated in details. Huang et al in [25] presented a wind turbine power generation system using a B2B converter with sensor-less vector control strategy.…”
Section: Introductionmentioning
confidence: 99%
“…In [21], dynamical behaviour of the scalar drivers was investigated by perturbation method; moreover, bifurcation diagrams were used for verifying the chaotic responses of the system. It should be mentioned that, this method is utilised for local stability analysis of the system and cannot show chaotic phenomena in the system.…”
Section: Introductionmentioning
confidence: 99%