2022
DOI: 10.1080/00268976.2022.2105270
|View full text |Cite
|
Sign up to set email alerts
|

Channel-specific core-valence projectors for determining partial Auger decay widths

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

6
25
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 8 publications
(31 citation statements)
references
References 64 publications
6
25
0
Order By: Relevance
“…We previously demonstrated that total and partial Auger decay widths can be extracted from CBF-EOMIP-CCSD wave functions of core-ionized states. [67][68][69] The decay is represented in these wave functions by 2h1p-excitations that fill the core hole. The resulting configurations give rise to the metastable character and are responsible for convergence problems when methods are used that do not treat the decay properly.…”
Section: Determination Of Auger Decay Widths With Complex-variable Me...mentioning
confidence: 99%
See 2 more Smart Citations
“…We previously demonstrated that total and partial Auger decay widths can be extracted from CBF-EOMIP-CCSD wave functions of core-ionized states. [67][68][69] The decay is represented in these wave functions by 2h1p-excitations that fill the core hole. The resulting configurations give rise to the metastable character and are responsible for convergence problems when methods are used that do not treat the decay properly.…”
Section: Determination Of Auger Decay Widths With Complex-variable Me...mentioning
confidence: 99%
“…To obtain the partial width for a channel, one needs to solve the EOMIP-CCSD equations for the core-ionized state under the constraint that the amplitudes for this particular channel are zero, which we previously referred to as Auger Channel Projector (ACP). 68 The difference in the total width with and without the channel being present is then interpreted as partial width.…”
Section: Determination Of Auger Decay Widths With Complex-variable Me...mentioning
confidence: 99%
See 1 more Smart Citation
“…[111][112][113][114] To compute partial Auger decay widths in the framework of the CBF approach, Matz and Jagau developed two different procedures. 76,77 The first one can be viewed as a generalization of CVS 35 . In this procedure, partial widths are evaluated by applying projectors that are specific to a particular Auger decay channel.…”
Section: Complex Basis Function Approachmentioning
confidence: 99%
“…In this procedure, partial widths are evaluated by applying projectors that are specific to a particular Auger decay channel. 77 The approach works well combined with CCSD, EOM-CCSD, and configuration interaction singles (CIS) wave functions but has the disadvantage that each decay channel requires a separate calculation.…”
Section: Complex Basis Function Approachmentioning
confidence: 99%