2020
DOI: 10.1364/boe.385016
|View full text |Cite
|
Sign up to set email alerts
|

Changes in temperature inside an optomechanical model of the human eye during emulated transscleral cyclophotocoagulation

Abstract: Currently, many diseases of the eye are treated by laser surgery. An understanding of light propagation and the heating of eye tissue during laser exposure is crucial to improving the outcome of these procedures. Here, we present the development of physical and computational models of the human eye by combining optical light propagation and thermal characteristics. For the physical model, all parts of the eye, including cornea, lens, ciliary body, sclera, aqueous and vitreous humors, and iris, were fabricated … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(16 citation statements)
references
References 36 publications
0
16
0
Order By: Relevance
“…Because TSCPC can cause thermal transfer from the sclera to the retina, its effect might be greater with higher energy levels, which leads to retinal thinning. 23 , 24 Therefore, our histologic studies revealed that MP-TSCPC directly affects the uvea, but indirectly affects the retina.…”
Section: Discussionmentioning
confidence: 78%
“…Because TSCPC can cause thermal transfer from the sclera to the retina, its effect might be greater with higher energy levels, which leads to retinal thinning. 23 , 24 Therefore, our histologic studies revealed that MP-TSCPC directly affects the uvea, but indirectly affects the retina.…”
Section: Discussionmentioning
confidence: 78%
“…Other non-optical modalities, such as ultrasound measurements (Ref. [ 52 ] reported ultrasound biomicroscopy for device characterization, and a dummy eye model for ultrasound biometry is commercially available at [ 90 ]), thermal measurements [ 70 ], or mechanical and structural characterizations [ 55 ], will not be considered in this review, unless the model itself presents relevant features related to optical measurements. Table 3 organizes the main modalities of the respective devices mentioned in this review.…”
Section: Measurement Modalities Of Eye Modelsmentioning
confidence: 99%
“…Table 3 organizes the main modalities of the respective devices mentioned in this review. Some devices are “multi-modal”, and more than one measurement modality was reported in the respective publications [ 28 , 35 , 37 , 41 , 42 , 48 , 52 , 55 , 64 , 70 , 72 , 80 ].…”
Section: Measurement Modalities Of Eye Modelsmentioning
confidence: 99%
See 2 more Smart Citations