2009
DOI: 10.1186/cc8195
|View full text |Cite
|
Sign up to set email alerts
|

Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo™/FloTrac™ device

Abstract: IntroductionPassive leg raising (PLR) is a simple reversible maneuver that mimics rapid fluid loading and increases cardiac preload. The effects of this endogenous volume expansion on stroke volume enable the testing of fluid responsiveness with accuracy in spontaneously breathing patients. However, this maneuver requires the determination of stroke volume with a fast-response device, because the hemodynamic changes may be transient. The Vigileo™ monitor (Vigileo™; Flotrac™; Edwards Lifesciences, Irvine, CA, U… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
88
0
2

Year Published

2010
2010
2023
2023

Publication Types

Select...
5
3
2

Relationship

0
10

Authors

Journals

citations
Cited by 132 publications
(91 citation statements)
references
References 33 publications
1
88
0
2
Order By: Relevance
“…The position of the patient during measurements was kept horizontal. CO, SVV, SVI, and SVR were recorded 20 sec after SAP, DAP, HR, and P ET CO 2 were recorded because the Vigileo™ samples the pressure waveform at 100 Hz over 20 sec to capture 2,000 data points for analysis, and parameter calculations are provided at the end of every 20-sec timeframe (20,21).…”
Section: Methodsmentioning
confidence: 99%
“…The position of the patient during measurements was kept horizontal. CO, SVV, SVI, and SVR were recorded 20 sec after SAP, DAP, HR, and P ET CO 2 were recorded because the Vigileo™ samples the pressure waveform at 100 Hz over 20 sec to capture 2,000 data points for analysis, and parameter calculations are provided at the end of every 20-sec timeframe (20,21).…”
Section: Methodsmentioning
confidence: 99%
“…Th is aspect is particularly true in septic patients in whom capillary leak may account for an attenuation of the PLR eff ects after one minute, as already described [22]. Th is is why clinical studies that ha ve tested the value of PLR to predict volume responsiveness used real-time hemodynamic measurements, such as aortic blood fl ow measured by esophageal Doppler [22,41], pulse contour analysis-derived ca rdiac output [16,26,42], cardiac output measured by bio reacta nce [4 3,44] or endotracheal bioimpedance cardi ograph y [45], subaortic blood velocity measured by echocardiography [46][47][48], ascending aortic velocity measure d by s uprasternal Doppler [49] and, more recently, end-tidal carbon dioxide [50,51].…”
Section: The Passive Leg-raising Testmentioning
confidence: 99%
“…The main finding of our systematic review are as follows: (1) The result of pooled sensi- (12) 0.97 (0.86 -1.00) Lamia (13) 0.77 (0.46 -0.95) Maizel (14) 0.88 (0.64 -0.99) Thiel (15) 0.81 (0.67 -0.91) Biais (17) 0.85 (0.62 -0.97) Préau (18) 0.86 (0.57 -0.98) Guinot (19) 0.85 (0.55 -0.98) Wang (21) 1.00 (0.86 -1.00) Monnet (22) 0.82 (0.57 -0.96) García (23) 0.95 (0.76 -1.00)…”
Section: Discussionmentioning
confidence: 99%