Changes in dynamic mitral valve geometry during percutaneous edge–edge mitral valve repair with the MitraClip system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
16
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 14 publications
(22 citation statements)
references
References 29 publications
6
16
0
Order By: Relevance
“…The acute effects of MitraClip on MV geometry under functional MR have been investigated in a few clinical studies using echo (Schmidt et al, 2013;Schueler et al, 2014;Noack et al, 2019b). Similar to these investigations, we found a marked reduction of the AP distance together with a relatively small increase of the AL-PM distance, especially when a ring was added (Table 1).…”
Section: Effects On MV Geometrysupporting
confidence: 83%
“…The acute effects of MitraClip on MV geometry under functional MR have been investigated in a few clinical studies using echo (Schmidt et al, 2013;Schueler et al, 2014;Noack et al, 2019b). Similar to these investigations, we found a marked reduction of the AP distance together with a relatively small increase of the AL-PM distance, especially when a ring was added (Table 1).…”
Section: Effects On MV Geometrysupporting
confidence: 83%
“…Such data about annular dynamics after MitraClip procedure are lacking in previous reports. 5,8 In particular Noak et al 10 have previously addressed the evaluation of AHCWR changes, with specific reference to the FMR cohort, but failed in recording any significant variation in the acute intra-procedural setting. Besides the use of newer devices, a possible explanation could be found in the higher percentage of clip implanted in our patients (> 1 clip implanted: 54.5% vs 32%).…”
Section: Fmr Cohortmentioning
confidence: 99%
“…Remy et al reported anteroposterior diameter reduction in the overall cohort, whereas only organic MR patients experienced a significant decrease regarding valve area (10). Other studies conducted exclusively in functional MR valves demonstrated a significant reduction in anteroposterior diameter (10,(15)(16)(17). A recently published analysis of 60 clip recipients showed significant overall reduction in both diameter and perimeter, without differences between etiologies (16).…”
Section: Discussionmentioning
confidence: 97%