Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Background/Objectives: This study compares the power of the radiofrequency (RF) signal reflected from the media layer (media power) of the common carotid artery (CCA) and the CCA stiffness between individuals with and without type 2 diabetes mellitus (T2DM). It also evaluates the associations of CCA media power with plasma glucose and lipid levels, as well as carotid stiffness. Methods: A total of 540 individuals, 115 with and 425 without T2DM (273 males, mean age = 64 ± 8 years) were studied using RF-based tracking of the right CCA. The following parameters were measured: CCA media thickness, luminal diameter, wall tensile stress (WTS), local pulse wave velocity (PWV), and media power. Results: Compared to the non-diabetic individuals, the T2DM patients had significantly higher CCA media thickness (652 ± 122 vs. 721 ± 138 microns, p < 0.005), luminal diameter (6.12 ± 0.78 vs. 6.86 ± 0.96 mm, p < 0.0005), media power (36.1 ± 4.8 vs. 39.3 ± 4.6, p < 0.0001), and PWV (7.65 ± 1.32 vs. 8.40 ± 1.89 m/s; p < 0.01), but comparable WTS (32.7 ± 10.4 vs. 33.1 ± 10.7 kPa; p = 0.25). In the entire population, CCA media power was independently associated with male sex, pulse pressure, current smoking, and T2DM; when T2DM was not included in the model, triglycerides emerged as an independent determinant of media power. The CCA PWV was independently associated with age, pulse pressure, media power, and T2DM. Conclusions: Our findings suggest the presence of structural changes in the arterial media of T2DM patients, leading to carotid stiffening and remodeling, aiming to preserve WTS. T2DM-related changes in arterial wall composition may be driven by high plasma triglyceride levels, which have previously been associated with both arterial stiffening and the incidence of CV events.
Background/Objectives: This study compares the power of the radiofrequency (RF) signal reflected from the media layer (media power) of the common carotid artery (CCA) and the CCA stiffness between individuals with and without type 2 diabetes mellitus (T2DM). It also evaluates the associations of CCA media power with plasma glucose and lipid levels, as well as carotid stiffness. Methods: A total of 540 individuals, 115 with and 425 without T2DM (273 males, mean age = 64 ± 8 years) were studied using RF-based tracking of the right CCA. The following parameters were measured: CCA media thickness, luminal diameter, wall tensile stress (WTS), local pulse wave velocity (PWV), and media power. Results: Compared to the non-diabetic individuals, the T2DM patients had significantly higher CCA media thickness (652 ± 122 vs. 721 ± 138 microns, p < 0.005), luminal diameter (6.12 ± 0.78 vs. 6.86 ± 0.96 mm, p < 0.0005), media power (36.1 ± 4.8 vs. 39.3 ± 4.6, p < 0.0001), and PWV (7.65 ± 1.32 vs. 8.40 ± 1.89 m/s; p < 0.01), but comparable WTS (32.7 ± 10.4 vs. 33.1 ± 10.7 kPa; p = 0.25). In the entire population, CCA media power was independently associated with male sex, pulse pressure, current smoking, and T2DM; when T2DM was not included in the model, triglycerides emerged as an independent determinant of media power. The CCA PWV was independently associated with age, pulse pressure, media power, and T2DM. Conclusions: Our findings suggest the presence of structural changes in the arterial media of T2DM patients, leading to carotid stiffening and remodeling, aiming to preserve WTS. T2DM-related changes in arterial wall composition may be driven by high plasma triglyceride levels, which have previously been associated with both arterial stiffening and the incidence of CV events.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.