2021
DOI: 10.3390/ma14020237
|View full text |Cite
|
Sign up to set email alerts
|

Change in Pull-Out Force during Resorption of Magnesium Compression Screws for Osteosynthesis of Mandibular Condylar Fractures

Abstract: Background: Magnesium has been used as degradable fixation material for osteosynthesis, but it seems that mechanical strength is still a current issue in these fixations. The aim of this study was to evaluate the axial pull-out force of compression headless screws made of magnesium alloy during their resorption. Methods: The tests included screws made for osteosynthesis of the mandible head: 2.2 mm diameter magnesium alloy MgYREZr (42 screws) and 2.5 mm diameter polylactic-co-glycolic acid (PLGA) (42 pieces, c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

5
2

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 69 publications
0
11
0
Order By: Relevance
“…Metallic resorbable osteosynthesis is under consideration [10]. This may be an important alternative to nonresorbable titanium fixation in the future [17].…”
Section: Resultsmentioning
confidence: 99%
“…Metallic resorbable osteosynthesis is under consideration [10]. This may be an important alternative to nonresorbable titanium fixation in the future [17].…”
Section: Resultsmentioning
confidence: 99%
“…The group of patients treated with magnesium alloy screws required, on average, a higher number of screws per fixation than the reference group due to the reasons cited above [31,40]. On the other hand, shorter magnesium screws were used than titanium screws.…”
Section: Discussionmentioning
confidence: 98%
“…The decrease in the pull-out force that occurs with the progression of screw resorption may cause early bone healing to be vulnerable to displacement, i.e., loss of mandible ramus height. For this reason, it seems clinically reasonable to investigate magnesium osteosynthesis and to recommend using more screws (Figure 1) and/or combining thinner screws of 1.8 mm with thicker screws, i.e., 2.3 or 3.2 mm [40].…”
Section: Discussionmentioning
confidence: 99%
“…The routine second surgical intervention in the treatment of fractures is to remove the fixation material [ 4 , 10 ]. In order to avoid the reoperation, a research was undertaken on the possibility of using fixation screws made of resorbable materials [ 42 , 43 ]. Promising results from recent studies indicate that the use of magnesium alloy screws can solve the issue of double operations and thus reduce postoperative complications [ 42 , 43 ].…”
Section: Discussionmentioning
confidence: 99%