Order By: Relevance
“…The Loom Jacking tools will be secured to existing threaded holes located in the welded rails used by the blanket cooling manifolds and "Edge Localized Mode" (ELM) coil support. [2] III. ASSEMBLY AND INSTALLATION STRATEGY The major design choice of the in-vessel electrical services was to pre-fabricate the loom, rather than individually install cables.…”
Section: Design Of the Conduit/loommentioning
confidence: 99%
“…The Loom Jacking tools will be secured to existing threaded holes located in the welded rails used by the blanket cooling manifolds and "Edge Localized Mode" (ELM) coil support. [2] III. ASSEMBLY AND INSTALLATION STRATEGY The major design choice of the in-vessel electrical services was to pre-fabricate the loom, rather than individually install cables.…”
Section: Design Of the Conduit/loommentioning
confidence: 99%