2013
DOI: 10.1016/j.enconman.2012.08.015
|View full text |Cite
|
Sign up to set email alerts
|

CFD analysis of pressure loss during flow by hydraulic directional control valve constructed from logic valves

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
35
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 67 publications
(35 citation statements)
references
References 4 publications
0
35
0
Order By: Relevance
“…These simulations revealed a rich variety of flow phenomena such as secondary patterns, hydrodynamic instabilities, turbulent pressure fluctuations due to vortex shedding, etc. Meanwhile, many researchers started to apply CFD method in the design and analyze other types of valves like hydraulic control valves and servo valves [17][18][19][20][21]. For instance, Lisowski and Rajda [20] investigated the pressure loss during flow by hydraulic directional control valve constructed from logic valves.…”
Section: Introductionmentioning
confidence: 99%
“…These simulations revealed a rich variety of flow phenomena such as secondary patterns, hydrodynamic instabilities, turbulent pressure fluctuations due to vortex shedding, etc. Meanwhile, many researchers started to apply CFD method in the design and analyze other types of valves like hydraulic control valves and servo valves [17][18][19][20][21]. For instance, Lisowski and Rajda [20] investigated the pressure loss during flow by hydraulic directional control valve constructed from logic valves.…”
Section: Introductionmentioning
confidence: 99%
“…The project is inspired by the solution of four-port directional control valve built of logic valves presented in the paper [16]. Four logic valves L1, L2, L3, L4 (Fig.…”
Section: The Design Of Multifunctional Directional Control Valve By Imentioning
confidence: 99%
“…Using a sufficient number of logic valves, theoretically, we can build a directional control valve for these advanced control functions [7,10,15]. Their assembly as a functional unit, such as four-port hydraulic directional control valve, is a relatively complex task [16]. Proposals of ready-made solutions are rare and, furthermore, does not take into account the applicable standards [17].…”
Section: Introductionmentioning
confidence: 99%
“…The ANSYS/Fluent software allows researchers to choose from a variety of models available including: k-ε, k-ω, Reynolds etc. In the case of flow through the directional control valve, k-ε model works well enough due to the fact that in the valve there are no conditions for the formation of laminar flow [5,8]. Thus, the k-ε turbulence model was chosen for the simulation study.…”
Section: Cfd Analysismentioning
confidence: 99%