2017
DOI: 10.1155/2017/3106278
|View full text |Cite
|
Sign up to set email alerts
|

CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor

Abstract: An innovative integrated passive safety system for a research reactor is proposed in this study to improve the safety of the research reactor. This integrated system has three functions in the facility as a decay tank, siphon breaker, and long-term cooling tank. This paper also deals with the process of designing and optimizing the decay tank and the siphon breaker of the integrated passive safety system. At first, the decay tank was designed and improved step by step, while considering the computational fluid… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…If we apply the same methodology used above to analyze the temperature field, that falls in the range [360.20,528.10] (in Kelvin), we get the intervals [1,3] and [1,40] calculated using the crosscorrelation, followed by thresholding of the differentiation. The best segment is [1,40], computed by solving expression (8). Then, we seek the optimum gamma to compute SPDMD dynamic modes using a list of 20𝛾 values logarithmically spaced from 10 to 600.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…If we apply the same methodology used above to analyze the temperature field, that falls in the range [360.20,528.10] (in Kelvin), we get the intervals [1,3] and [1,40] calculated using the crosscorrelation, followed by thresholding of the differentiation. The best segment is [1,40], computed by solving expression (8). Then, we seek the optimum gamma to compute SPDMD dynamic modes using a list of 20𝛾 values logarithmically spaced from 10 to 600.…”
Section: Resultsmentioning
confidence: 99%
“…More recently the occurrence of the natural circulation in nuclear research reactors has been described in the literature by studies focusing mainly: the prevention of a severe accident [8], the effect of an unprotected reactivity insertion on the dynamic response of Materials Testing Reactor -MTR research reactors under natural circulation regime [9], the investigation of flow reversal from downward forced to upward natural circulation [10], the stability of the natural circulation and its suppression due to the presence of oscillations [11], [12].…”
Section: Introductionmentioning
confidence: 99%
“…In the forced convection, the primary cooling system is designed to have a downward flow through the core channel for normal operation [1,5,6].…”
Section: Introductionmentioning