2016
DOI: 10.1007/s11999-015-4683-1
|View full text |Cite|
|
Sign up to set email alerts
|

Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion

Abstract: BackgroundMetal release resulting from taper fretting and corrosion is a clinical concern, because wear and corrosion products may stimulate adverse local tissue reactions. Unimodular hip arthroplasties have a conical taper between the femoral head (head bore taper) and the femoral stem (stem cone taper). The use of ceramic heads has been suggested as a way of reducing the generation of wear and corrosion products from the head bore/stem cone taper junction. A previous semiquantitative study found that ceramic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

4
59
3

Year Published

2017
2017
2021
2021

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 71 publications
(67 citation statements)
references
References 20 publications
4
59
3
Order By: Relevance
“…Black synovial fluid from a hip aspiration appears to be associated with impending GTF requiring a complete revision of the femoral stem as compared to a femoral head and liner exchange, allowing appropriate preoperative planning. Based on this experience, we have changed our clinical practice from using CoCr femoral heads to ceramic heads based on the lower risk of corrosion and metal release[29, 30], which should theoretically mitigate ALTR issues in the future.…”
Section: Discussionmentioning
confidence: 99%
“…Black synovial fluid from a hip aspiration appears to be associated with impending GTF requiring a complete revision of the femoral stem as compared to a femoral head and liner exchange, allowing appropriate preoperative planning. Based on this experience, we have changed our clinical practice from using CoCr femoral heads to ceramic heads based on the lower risk of corrosion and metal release[29, 30], which should theoretically mitigate ALTR issues in the future.…”
Section: Discussionmentioning
confidence: 99%
“…However, a weaker correlation has been observed with the more severely damaged femoral head bores, specifically those with a score of 3 or 4 [23, 24]. To compare the material loss between the smaller cohort of the 14 most highly damaged implants, we chose to describe the maximum depth of material loss of these components by calculating the best fit of the femoral head bore at different z heights along the taper.…”
Section: Discussionmentioning
confidence: 99%
“…In particular, ceramic femoral heads are suitable to be used as the articulating surface in THAs due to their hardness and wettability, lower friction, and higher wear resistance . Several retrieval studies recently reported that metal fretting and corrosion from the head–neck junction may be mitigated by using a ceramic femoral head . Moreover, alumina and ZTA ceramics have high chemical stability, such as high corrosion resistance.…”
Section: Introductionmentioning
confidence: 99%
“…11,12 Several retrieval studies recently reported that metal fretting and corrosion from the head-neck junction may be mitigated by using a ceramic femoral head. 14,15 Moreover, alumina and ZTA ceramics have high chemical stability, such as high corrosion resistance. It has also been suggested that Ti-6Al-4V alloy stem neck tapers may cause more galvanic corrosion than Co-Cr-Mo stem neck tapers when used in conjunction with a Co-Cr-Mo femoral head.…”
Section: Introductionmentioning
confidence: 99%