1999
DOI: 10.1109/87.784420
|View full text |Cite
|
Sign up to set email alerts
|

Centrifugal compressor surge and speed control

Abstract: Abstract-Previous work on stabilization of compressor surge is extended to include control of the angular velocity of the compressor. First a low-order centrifugal compressor model is presented where the states are mass flow, pressure rise, and rotational speed of the spool. Energy transfer considerations are used to develop a compressor characteristic. In order to stabilize equilibria to the left of the surge line, a close coupled valve is used in series with the compressor. Controllers for the valve pressure… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
81
0
1

Year Published

2002
2002
2015
2015

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 134 publications
(86 citation statements)
references
References 22 publications
1
81
0
1
Order By: Relevance
“…Finalmente, en especial por las propiedades de los sensores utilizados y por la naturaleza de la señal, recomiendan como mejor opción el análisis de la presión. Tomando en consideración que el bombeo profundo tiene una frecuencia que está dentro de los 5 a 15 Hz dependiendo de las geometrías implicadas [43], se propone realizar un estudio espectral de la señal mediante Fourier. Así, cuando el bombeo ocurre se tiene que las frecuencias preponderantes en la señal son la de bombeo y la de apertura y cierre de las válvulas del motor.…”
Section: Sección 24unclassified
“…Finalmente, en especial por las propiedades de los sensores utilizados y por la naturaleza de la señal, recomiendan como mejor opción el análisis de la presión. Tomando en consideración que el bombeo profundo tiene una frecuencia que está dentro de los 5 a 15 Hz dependiendo de las geometrías implicadas [43], se propone realizar un estudio espectral de la señal mediante Fourier. Así, cuando el bombeo ocurre se tiene que las frecuencias preponderantes en la señal son la de bombeo y la de apertura y cierre de las válvulas del motor.…”
Section: Sección 24unclassified
“…This model was further developed by Fink et al (1992) in order to include the dynamic of the rotating shaft connecting driver and compressor. Gravdahl and Egeland (1999) proposed a further modification by expressing the torque of the compressor as a function of shaft rotational velocity and mass flow rate while Gravdahl et al (2002) proposed to use the torque of the driver as input variable of the model instead of the rotational shaft speed . This last model was the reference for this work and was modified according to Morini et al (2007) in order to include also the recycle loop.…”
Section: Mathematical Model Of the Compressormentioning
confidence: 99%
“…The test system records status data of the compressor under different work conditions. By calculating the characteristic curve through that data and comparing the curve with the designed parameters, the performance of the impeller can be effectively evaluated [1] [2]. Fig.1 shows the general structure of the system.…”
Section: Systyem Sturcturementioning
confidence: 99%