2015
DOI: 10.1049/iet-gtd.2015.0720
|View full text |Cite
|
Sign up to set email alerts
|

Centralised solution for subsynchronous control interaction of doubly fed induction generators using voltage‐sourced converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 44 publications
(21 citation statements)
references
References 23 publications
0
21
0
Order By: Relevance
“…In this case, the triggering condition was similar to the one experienced in Texas, i.e., after a fault on the system the wind farm became radially connected with a corridor with 60% of series compensation [22]. Another incident was reported in the north of China, where a 3000 MVA wind generation (composed mostly of DFIG turbines) experienced very low-frequency oscillations [23,24]. The problem was associated to SSI and in this case, the oscillations vanished after the successive disconnection of generation units.…”
Section: Introductionmentioning
confidence: 57%
See 1 more Smart Citation
“…In this case, the triggering condition was similar to the one experienced in Texas, i.e., after a fault on the system the wind farm became radially connected with a corridor with 60% of series compensation [22]. Another incident was reported in the north of China, where a 3000 MVA wind generation (composed mostly of DFIG turbines) experienced very low-frequency oscillations [23,24]. The problem was associated to SSI and in this case, the oscillations vanished after the successive disconnection of generation units.…”
Section: Introductionmentioning
confidence: 57%
“…Notice that when 94.8% [bifurcation G(ī r ) in Fig. 5(c)], the cycle grazes the boundary 24 and t 2 = t 3 . On the other hand at the non-smooth saddle-node point NSN( i r ) for 90%, the cycle grazes the boundary 12 and t 1 = t 4 .…”
Section: Time-domain Simulations Of Switching Limit Cyclesmentioning
confidence: 99%
“…2 [31][32]. (3) Sub-synchronous Damper (SSD): Additional power electronic converters can be connected to wind farms to dissipate the resonance power of SSI [33]. The working principle is similar to an active filter, which absorbs (or counters) the sub-synchronous components.…”
Section: B Additional Series Capacitors Between South East and Paramentioning
confidence: 99%
“…In fact, the electromagnetic oscillation is one of the typical problems in power electronized power systems [1,2]. In the point view of oscillation frequency, the oscillation phenomenon in CTAIP is similar to the oscillation caused by subsynchronous control interaction (SSCI) [3,4]. There has been a large number of studies focused on SSCI.…”
Section: Introductionmentioning
confidence: 99%