Central Venous Catheters: Do we need to Review Practice on Positioning?

Abstract: It is generally agreed that the tip of an inserted central venous catheter (CVC) should not lie within the right atrium. However, the tip of a CVC not inserted to an adequate depth could lie outside the superior vena cava, predisposing to thrombus formation and infection. A retrospective audit of the position of CVCs on chest radiographs in intensive care patients and the associated incidence of catheter-related infections was therefore undertaken. Chest radiographs of 100 patients who had central venous cathe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
22
0
1

Year Published

2009
2009
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(23 citation statements)
references
References 12 publications
0
22
0
1
Order By: Relevance
“…(1) There are more than 200,000 CVC insertions annually in the United Kingdom and 6 million in the United States. (2) However, an often overlooked potential complication is the inadvertent total loss travascularly of part of the CVC set-a long, flexible, metal guidewire. Guidewire retention has been reported at a rate of 1 in 3,291 procedures in one medical establishment, (3) although the actual incidence may be even higher due to underreporting.…”
Section: Central Venous Catheterizationmentioning
confidence: 99%
See 1 more Smart Citation
“…(1) There are more than 200,000 CVC insertions annually in the United Kingdom and 6 million in the United States. (2) However, an often overlooked potential complication is the inadvertent total loss travascularly of part of the CVC set-a long, flexible, metal guidewire. Guidewire retention has been reported at a rate of 1 in 3,291 procedures in one medical establishment, (3) although the actual incidence may be even higher due to underreporting.…”
Section: Central Venous Catheterizationmentioning
confidence: 99%
“…CVC is a commonly used medical procedure to gain access to a patient's venous system for a wide range of purposes such as delivering intravenous medication and taking measurements . There are more than 200,000 CVC insertions annually in the United Kingdom and 6 million in the United States . However, an often overlooked potential complication is the inadvertent total loss travascularly of part of the CVC set—a long, flexible, metal guidewire.…”
Section: Introductionmentioning
confidence: 99%
“…Malpositioning of the tip of the central venous catheter often leads to erroneous measurement, leading to an incorrect volume replacement and other serious complications, like cardiac tamponade or dysrhythmias, caused by the interaction with the wall of the vessel or the endocardium. [13]…”
mentioning
confidence: 99%
“…The correct position of the tip of CVC should be in the superior vena cava, above the level of pericardial reflection to obtain true CVP measurements. [1] An angle greater than 40° can cause perforation of wall of the blood vessel. [4]…”
mentioning
confidence: 99%
“…The central venous pressure (CVP) monitoring is a useful tool for assessment of the status of intravascular volume. Of the tip of the central venous catheter often leads to erroneous measurement, leading to an incorrect volume replacement and other serious complications, like cardiac tamponade or dysrhythmias, caused by the interaction with the wall of the vessel or the endocardium [1][2][3].…”
mentioning
confidence: 99%