2014
DOI: 10.1111/vop.12206
|View full text |Cite
|
Sign up to set email alerts
|

Central corneal thickness and intraocular pressure in captive black‐footed penguins (Spheniscus dermersus)

Abstract: Ultrasound pachymetry has shown to be a reliable and easy technique to measure CCT in penguins. No correlation was observed between IOP and CCT values in this study. IOP showed a significant but weak decrease as age increased in the black-footed penguin.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
16
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(18 citation statements)
references
References 25 publications
1
16
1
Order By: Relevance
“…Considering the differences in the present study between young and adult birds, a study in three week old chickens, showed IOP values of 17.51±0.13 mmHg, that did not differ significantly with broiler and layer chickens lines (Prashar et al, 2007), but again it should be noted that these are not water birds. In one study of captive black-footed penguins (Spheniscus dermersus) tonometry showed a much higher IOP (31.77±3.3 mmHg) than in our study (Gonzales-Alonso-Alegre et al, 2015), and a later publication of ocular findings and reference values in penguins showed IOP measured with the Tonovet tonometer "d" calibration to be 29.1±7.16 mmHg in Macaroni and 24.1±5.09 mmHg in Rockhopper penguin, both higher than in swans evaluated here (Bliss et al, 2015). A more recent research study on IOP in ducks and geese showed the average IOP to be 10.2±2.2 mmHg in ducks and 9.1±2.0 mmHg in geese, measured with TonoVet tonometer (calibrated at the "d" setting as in the current study) giving results similar to those in the present study (Mood et al, 2016).…”
Section: Methodscontrasting
confidence: 81%
“…Considering the differences in the present study between young and adult birds, a study in three week old chickens, showed IOP values of 17.51±0.13 mmHg, that did not differ significantly with broiler and layer chickens lines (Prashar et al, 2007), but again it should be noted that these are not water birds. In one study of captive black-footed penguins (Spheniscus dermersus) tonometry showed a much higher IOP (31.77±3.3 mmHg) than in our study (Gonzales-Alonso-Alegre et al, 2015), and a later publication of ocular findings and reference values in penguins showed IOP measured with the Tonovet tonometer "d" calibration to be 29.1±7.16 mmHg in Macaroni and 24.1±5.09 mmHg in Rockhopper penguin, both higher than in swans evaluated here (Bliss et al, 2015). A more recent research study on IOP in ducks and geese showed the average IOP to be 10.2±2.2 mmHg in ducks and 9.1±2.0 mmHg in geese, measured with TonoVet tonometer (calibrated at the "d" setting as in the current study) giving results similar to those in the present study (Mood et al, 2016).…”
Section: Methodscontrasting
confidence: 81%
“…The aim of the systematic review was to collect typical IOPs for healthy adult species of vertebrates; therefore, some aspects of the variations in IOP within each group of vertebrates were not included in the study. While in healthy animals the IOP is generally not significantly different in the left and right eye [ 40 , 41 , 43 , 53 , 56 59 , 64 66 , 69 , 74 76 , 79 , 85 , 88 , 91 , 92 , 98 , 103 , 111 , 114 , 114 , 117 , 122 127 , 132 ] or in males and females [ 41 , 43 , 56 , 58 , 63 , 65 , 69 , 74 , 75 , 79 , 85 , 88 , 91 , 92 , 103 , 114 , 121 124 , 126 , 132 , 133 ], it has been found to change with position in flamingos and bats. [ 59 , 60 , 114 ].…”
Section: Discussionmentioning
confidence: 99%
“…The TonoVet ® setting can be ‘d’ (dog/cat), ‘h’ (horse), or ‘p’ (undefined). In avian studies comparing ‘d’ and ‘p’, ‘d’ is found to read higher than ‘p’, and in studies comparing ‘d’ and ‘h’, results have varied . Most studies in avian ophthalmology have used the ‘d’ setting .…”
Section: Discussionmentioning
confidence: 99%
“…In avian studies comparing ‘d’ and ‘p’, ‘d’ is found to read higher than ‘p’, and in studies comparing ‘d’ and ‘h’, results have varied . Most studies in avian ophthalmology have used the ‘d’ setting . Studies with captive black‐footed penguins and Humboldt penguins have found the mean IOP with ‘d’ setting to be between 20.3 and 31.7 mmHg .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation