2018
DOI: 10.1016/j.arth.2018.01.041
|View full text |Cite
|
Sign up to set email alerts
|

Cementless Total Hip Arthroplasty in Crowe III and IV Dysplasia: High Hip Center and Modular Necks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
50
0
4

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 58 publications
(57 citation statements)
references
References 23 publications
3
50
0
4
Order By: Relevance
“…Because it is difficult to reconstruct the hip center at its original position in type IV DDH cases involving a small, shallow true acetabulum, the high hip technique, wherein the acetabulum is reconstructed superior to the anatomic one, may be employed. Using a high hip center technique in a cohort of 84 patients, Montalti and colleagues obtained mean vertical and horizontal distances from the rotational center of 33 ± 8 mm and 30 ± 5 mm in type III DDH cases and IV DDH cases, respectively. After 15 years, revision was performed in only 2 of those cases due to aseptic loosening (one cup and one stem).…”
Section: Direct Anterior Approach Total Hip Arthroplastymentioning
confidence: 99%
See 2 more Smart Citations
“…Because it is difficult to reconstruct the hip center at its original position in type IV DDH cases involving a small, shallow true acetabulum, the high hip technique, wherein the acetabulum is reconstructed superior to the anatomic one, may be employed. Using a high hip center technique in a cohort of 84 patients, Montalti and colleagues obtained mean vertical and horizontal distances from the rotational center of 33 ± 8 mm and 30 ± 5 mm in type III DDH cases and IV DDH cases, respectively. After 15 years, revision was performed in only 2 of those cases due to aseptic loosening (one cup and one stem).…”
Section: Direct Anterior Approach Total Hip Arthroplastymentioning
confidence: 99%
“…Using a high hip center technique in a cohort of 84 patients, Montalti and colleagues obtained mean vertical and horizontal distances from the rotational center of 33 ± 8 mm and 30 ± 5 mm in type III DDH cases and IV DDH cases, respectively. After 15 years, revision was performed in only 2 of those cases due to aseptic loosening (one cup and one stem). Galea et al .…”
Section: Direct Anterior Approach Total Hip Arthroplastymentioning
confidence: 99%
See 1 more Smart Citation
“…According to these authors, the EP's anatomical positioning ensures the proper functioning of the gluteal muscles, allowing walking without pronounced limping. Others like Montalti et al (2018) argue that the AC-EP can be inserted into the joint's secondary socket. Harris et al (1998) and Bozic et al (2004) have the same opinion regarding very serious cases of dysplasia.…”
Section: Introductionmentioning
confidence: 99%
“…Деформированная вертлужная впадина затрудняет интраоперационную ориентацию вертлужного компонента тотального эндопротеза тазобедренного сустава, а наличие выраженных дефектов уменьшает возможности фиксации имплантата [1,2,3]. чем значительнее анатомические изменения вертлужной впадины, тем чаще для оптимизации фиксации требуется нестандартное размещение вертлужного компонента [4,5,6,7,8], приводящее к малопрогнозируемым изменениям биомеханики [9,10,11].…”
Section: Introductionunclassified