Cellular point-of-care diagnostics using an inexpensive layer-stack microfluidic device

Abstract: Passively pumped layer stack microfluidics allow for simple, inexpensive cyclic imaging with reduced reagent usage.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 28 publications
0
8
0
Order By: Relevance
“…We developed a specially constructed flow chamber to facilitate rapid cycling and preservation of reagents, with no need for harsh conditions (e.g., paraformaldehyde to fix and adhere EVs or hydrogen peroxide to bleach fluorochromes), thus allowing unequivocal analyses of a single EV. This chamber uses an acrylic pressure-sensitive adhesive to bond a treated coverglass to a microscope slide 28 . The shape of the pressure-sensitive adhesive (width 4 mm, length 12 mm, height 50 µm) allows pump-free flushing with flow rates of ∼ 1 µL/s within the ∼2 µL channel.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…We developed a specially constructed flow chamber to facilitate rapid cycling and preservation of reagents, with no need for harsh conditions (e.g., paraformaldehyde to fix and adhere EVs or hydrogen peroxide to bleach fluorochromes), thus allowing unequivocal analyses of a single EV. This chamber uses an acrylic pressure-sensitive adhesive to bond a treated coverglass to a microscope slide 28 . The shape of the pressure-sensitive adhesive (width 4 mm, length 12 mm, height 50 µm) allows pump-free flushing with flow rates of ∼ 1 µL/s within the ∼2 µL channel.…”
Section: Resultsmentioning
confidence: 99%
“…The coverglass surface was maximally activated for subsequent attachment of EV. Microfluidic devices were prepared following a recent description of an inexpensive device for cell staining 28 . Channels were cut from 50 µm thick double-sided 3M VHB adhesive tape (F9460PC) using a Silhouette Cameo 4 craft cutting tool (Silhouette USA).…”
Section: Device Fabrication and Assemblymentioning
confidence: 99%
See 1 more Smart Citation
“…Lately, double-sided adhesives (DSA) based micro uidic fabrication strategies are being developed for multilayered microphysiological systems and cellular diagnostics (Hosic et al 2021;Lucas et al 2022).…”
Section: Introductionmentioning
confidence: 99%
“…There is minimal bleed through of signal into consecutive cycles, providing an effective method for multiplexed imaging and cancer diagnosis. Reproduced with permission [7]. Copyright 2022, Royal Society of Chemistry.…”
mentioning