2004 Conference on Precision Electromagnetic Measurements 2004
DOI: 10.1109/cpem.2004.305554
|View full text |Cite
|
Sign up to set email alerts
|

CCEM Key Comparison CCEM.RF-K10.CL (GT/RF 99-2) Power in 50 ¿ Coaxial Lines, Frequency: 50 MHz to 26 GHz

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
10
0
2

Year Published

2009
2009
2015
2015

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(13 citation statements)
references
References 1 publication
1
10
0
2
Order By: Relevance
“…This definition reduces to the typical one given in [19] for bolometers, if we identify P M with the power measured by dc-power substitution. On the other side, we demonstrated in [15] that (1) matches perfectly the alternative definition assumed in [11].…”
Section: Measurand Definition Andsupporting
confidence: 62%
See 2 more Smart Citations
“…This definition reduces to the typical one given in [19] for bolometers, if we identify P M with the power measured by dc-power substitution. On the other side, we demonstrated in [15] that (1) matches perfectly the alternative definition assumed in [11].…”
Section: Measurand Definition Andsupporting
confidence: 62%
“…Conversely, for the thermoelectric power sensor an appropriate definition has been given in the international exercise CCEM.RF-K10.CL [11].…”
Section: Measurand Definition Andmentioning
confidence: 99%
See 1 more Smart Citation
“…In [8], an alternative definition for the effective efficiency is given, which relates a dc (or low frequency) substitution power P dc,sub entering the sensor via its input to the absorbed RF power whereby both powers produce the same thermopile output voltage V th…”
Section: A Definitionmentioning
confidence: 99%
“…Afin de pallier cette contrainte, l'utilisation d'un thermocouple remplaçant la thermistance apparaît comme une solution cohérente pour des caractérisations dans les basses fréquences. Des détecteurs de puissance basés sur les thermocouples à chauffage indirect ont fait l'objet d'une comparaison internationale (CCEM.RF-K10.CL) [2] dans laquelle a été expérimenté pour la première fois un microcalorimètre symétrique sur ligne coaxiale spécialement optimisé pour ce type de capteurs. Les résultats de cette comparaison ont permis de conclure que ces sondes étaient une réelle alternative aux thermistances afin de réaliser un étalon de puissance jusqu'à 26,5 GHz.…”
Section: Introductionunclassified