1999
DOI: 10.1016/s0003-2670(99)00037-9
|View full text |Cite
|
Sign up to set email alerts
|

CCD-camera based capillary chemiluminescent detection of retinol binding protein

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0
6

Year Published

2007
2007
2022
2022

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(22 citation statements)
references
References 20 publications
0
16
0
6
Order By: Relevance
“…Digital image analyses are found for analytical methods in different matrices [17][18][19][20][21][22][23][24][25][26][27][28][29][30] and also for environmental monitoring and remote sensing [31,32]. For instance, Paciornik et al [31] quantified Hg in fish samples using analysis of color descriptors (Hue-Lightness-Saturation, HLS and Cyan-MagentaYellow, CMY) from digital images of a spot test system.…”
Section: Introductionmentioning
confidence: 99%
“…Digital image analyses are found for analytical methods in different matrices [17][18][19][20][21][22][23][24][25][26][27][28][29][30] and also for environmental monitoring and remote sensing [31,32]. For instance, Paciornik et al [31] quantified Hg in fish samples using analysis of color descriptors (Hue-Lightness-Saturation, HLS and Cyan-MagentaYellow, CMY) from digital images of a spot test system.…”
Section: Introductionmentioning
confidence: 99%
“…Others solid state detectors could also be considered, like CMOS photodiodes, Avalanche photodiodes, etc [21][22][23][24][25]. A straightforward comparison of the efficiency of different systems is not always possible because of the varying targeted reactions and biomarkers (glucose, lactate, cells, etc) and their typical concentrations in the analytical sample, as well as the different methods (chemiluminescence, fluorescence, electroluminescence, etc) and purposes (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…wearable or disposable device or laboratory instruments) involved. In [24], for example, which discusses an ELISA test with very good sensitivity, a CCD camera cooled at −45 • C is used in combination with chemiluminescence and immobilization of antibodies in capillary tubes.…”
Section: Introductionmentioning
confidence: 99%
“…However, their size, supply voltage and power consumption are too high to be used in portable instruments. Another alternative are CCD cameras, as reported Momeni et al [14]. The main disadvantage of CCD cameras is that they need to work at temperatures of tens of Celsius degrees below 0º to achieve a good resolution; they are also complex to use and process, making them of limited interest for portable instruments.…”
Section: Introductionmentioning
confidence: 99%