2019
DOI: 10.1016/j.optlastec.2018.10.034
|View full text |Cite
|
Sign up to set email alerts
|

Cavity design peculiarities and influence of SESAM characteristics on output performances of a Nd:YVO4 mode locked laser oscillator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…Additionally, a wedged Nd:LGSB crystal may lead to reduced etalon effects and stronger selectivity of the oscillating modes, thus outputting a stable ML operation with shorter transform limited pulses. In this respect, further mode locking experiments on Nd:LGSB crystal samples with one or two wedged facets, analogous to our previous studies on wedge-cut Nd:YVO 4 crystals [36], will be performed.…”
Section: Resultsmentioning
confidence: 86%
See 2 more Smart Citations
“…Additionally, a wedged Nd:LGSB crystal may lead to reduced etalon effects and stronger selectivity of the oscillating modes, thus outputting a stable ML operation with shorter transform limited pulses. In this respect, further mode locking experiments on Nd:LGSB crystal samples with one or two wedged facets, analogous to our previous studies on wedge-cut Nd:YVO 4 crystals [36], will be performed.…”
Section: Resultsmentioning
confidence: 86%
“…A further increase of the pump power drastically reduced the output, indicating that the resonator had reached the edge of the stability zone (in accordance with the resonator design). The laser crystal was uncoated and it was also not wedged [36]. The etalon effects could, therefore, be responsible for the mixed CML/QML behavior.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…[12]. Under the above experimental conditions, the stability of the laser resonator is judged by the ABCD matrix method [17] (the thermal focal length of the crystal was 500 mm at low pump power and 230 mm at high pump power). We measured the beam quality factor M 2 at the full output power of 8.7 W, taking advantage of the knife-edge method.…”
Section: Resultsmentioning
confidence: 99%
“…[12]. Under the above experimental conditions, the stability of the laser resonator is judged by the ABCD matrix method [17] (the thermal focal length of the crystal was 500 mm at low pump power and 230 mm at high pump power). mirrors (shown in the Figure 4) were measured with the spectrum analyzer Bristol 721A (with a resolution of ±0.2 ppm).…”
Section: Resultsmentioning
confidence: 99%