Cavitation in Biomedicine 2015
DOI: 10.1007/978-94-017-7255-6_2
|View full text |Cite
|
Sign up to set email alerts
|

Cavitation Mapping

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 98 publications
0
5
0
Order By: Relevance
“…When the divalent anion and oxygen react, nitrogen is separated and an unstable organic peroxide is formed, which is in an excited state. At this time, electrons are transferred from the excited state to the ground state, and energy is emitted as light (BLUE light) in this process [18] , [19] . Since the amount of LE is related to the amount of OH* FR, the amount of OH* FR can be estimated by measuring the LE [13] , [20] .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…When the divalent anion and oxygen react, nitrogen is separated and an unstable organic peroxide is formed, which is in an excited state. At this time, electrons are transferred from the excited state to the ground state, and energy is emitted as light (BLUE light) in this process [18] , [19] . Since the amount of LE is related to the amount of OH* FR, the amount of OH* FR can be estimated by measuring the LE [13] , [20] .…”
Section: Methodsmentioning
confidence: 99%
“…When luminol is added to an alkaline solution, it reacts with FR to release SCL. In this experiment, an alkaline solution was used in which sodium carbonate (Na2CO3) was dissolved and the pH was adjusted to 14 [18] . Based on Negishi [18] , a luminol solution was prepared by dissolving 2.5 g of sodium carbonate in 500 mL of distilled water to dissolve luminol well, and then completely dissolving 0.1 g of luminol.…”
Section: Methodsmentioning
confidence: 99%
“…Cavitation Measurement Apparatus. Cavitation measurements were carried out using a setup based on passive cavitation detection (PCD) 51 developed by InSightec Ltd., Israel (Figure S3). A US transducer tile (32 × 32 mm 2 , InSightec Ltd., Israel) was placed at the bottom of a chamber filled with degassed water and operated in pulse wave mode.…”
Section: Methodsmentioning
confidence: 99%
“…Calibration of the mass spectrometer in terms of the absolute isotope amount ratios was performed by gravimetric mixing of sulphur-isotope-enriched compounds. 60,61 In this way, the values of RMs (within some uncertainty) may be reproduced based on the method itself, regardless of potential drifts or even losses of artefactbased RMs covering the δ 34 S range.…”
Section: Vcdt Scale For δ 34 Smentioning
confidence: 99%
“…4,58 Determinations of the δ 34 S values in IAEA-S-2 and IAEA-S-3 were performed by several laboratories, by using mass spectrometry on SO 2 and SF 6 analyte gas and by double-spike MC-TIMS (see Mann et al 59 and references cited therein). Pioneering determinations of absolute isotope amount ratios in these materials were based on conversion into SF 6 by fluorination 60,61 ; determinations are done on the SF 5 + fragment ion which does not require an isobaric correction (fluorine is monoisotopic). Calibration of the mass spectrometer in terms of the absolute isotope amount ratios was performed by gravimetric mixing of sulphur-isotope-enriched compounds.…”
Section: Vcdt Scale For δ 34 Smentioning
confidence: 99%