2008
DOI: 10.1016/j.saa.2007.08.006
|View full text |Cite
|
Sign up to set email alerts
|

Cation complexation behavior of pyrene- and anthracene-appended new crown ether derivatives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
16
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(16 citation statements)
references
References 20 publications
0
16
0
Order By: Relevance
“…These types of sensors can be roughly categorized into three groups based on their response to metal ions. The first two sensor groups are those that undergo turn-ON (17)(18)(19)(20)(21)(22)(23)(24) or turn-OFF responses (25)(26)(27) typically caused by the removal or installation of photoinduced electron transfer (PET) or heavy atom effect promoted quenching pathways. In the third group, sensing is based on monomer/excimer emission switching (28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40)(41)(42)(43) induced by changes in spatial distances between two pyrene moieties.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…These types of sensors can be roughly categorized into three groups based on their response to metal ions. The first two sensor groups are those that undergo turn-ON (17)(18)(19)(20)(21)(22)(23)(24) or turn-OFF responses (25)(26)(27) typically caused by the removal or installation of photoinduced electron transfer (PET) or heavy atom effect promoted quenching pathways. In the third group, sensing is based on monomer/excimer emission switching (28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40)(41)(42)(43) induced by changes in spatial distances between two pyrene moieties.…”
Section: Introductionmentioning
confidence: 99%
“…In the third group, sensing is based on monomer/excimer emission switching (28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40)(41)(42)(43) induced by changes in spatial distances between two pyrene moieties. Moreover, the pyrene and crown ether groups in these types of sensors are normally linked by flexible chains, such as methylene (17)(18)(19)(20)(21)28,29,(44)(45)(46), ether (30,47,48), oligoethylene glycol (31)(32)(33)(34), ester (22), amine (49), amide (25)(26)(27)(35)(36)(37)(38)(39)(40)(41)50), imine (23), triazole (51), sulfoxide (24) and DNA…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Crown ethers have been used as a recognition moiety in fluorescent chemosensors [22][23][24][25][26]. The structure having p-conjugation systems such as pyrene, anthracene, dansyl, and coumarine has been used as signaling moiety.…”
Section: Introductionmentioning
confidence: 99%