Abstract: We describe a cathodoluminescence spectrometer that is attached to an analytical transmission electron microscope. After a brief consideration of the set-up and the peculiarities of recording spectra and of mapping defect distributions in panchromatic and monochromatic cathodoluminescence, we discuss two examples of applications. Emphasis is placed on the potential for obtaining novel information about materials and processes on a microscopic and a nanoscopic scale by combining cathodoluminescence with the str… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 19 publications
0
14
0
Order By: Relevance
“…There have also been many CL studies directly implicating dislocation cores as nonradiative recombination centers (Albrecht et al 2002;Cherns et al 2001;Ponce et al 1996Ponce et al 2003Strunk et al 2006;Yamamoto et al 2003). However it seems that many fundamental questions remain.…”
Section: Future Directionsmentioning
confidence: 95%
See 1 more Smart Citation
“…There have also been many CL studies directly implicating dislocation cores as nonradiative recombination centers (Albrecht et al 2002;Cherns et al 2001;Ponce et al 1996Ponce et al 2003Strunk et al 2006;Yamamoto et al 2003). However it seems that many fundamental questions remain.…”
Section: Future Directionsmentioning
confidence: 95%
“…Identification of dislocations as sources of nonradiative recombination has been by comparison to transmitted electron images taken in the TEM or STEM, (Albrecht et al 2002;Cherns et al 2001;Lakner et al 1988;Ponce et al 1996Ponce et al , 2003Strunk et al 2006;Yamamoto et al 2003). Other methods also exist for local mapping of luminescence, for example the scanning near-field optical microscope or the scanning tunneling microscope, see Gustafsson et al (1998) for a review of these techniques.…”
Section: Studies Of Dislocationsmentioning
confidence: 98%
“…(e.g. Haegel et al , 2004; Gustafsson, 2006; Strunk et al , 2006; Diaz‐Guerra et al , 2007). An impact of long‐range effects of resistances on CL measurements has not been analysed yet.…”
Section: Dependencementioning
confidence: 99%
“…Conventionally CL imaging has been conducted with SEM, where the CL emission from specimens is collected through the parabolic mirror to generate a scanning image. Though CL images generated with TEM were once claimed (Yamamoto 2002;Strunk et al, 2006), what was actually done was a CL imaging with the scanning mode of STEM(STEM-CL). The type of CL imaging shown in this paper must be the first one ever reported.…”
Section: Introductionmentioning
confidence: 99%