2020
DOI: 10.1109/tbme.2019.2908031
|View full text |Cite
|
Sign up to set email alerts
|

Catheter-Based Polarization Sensitive Optical Coherence Tomography Using Similar Mueller Matrix Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 30 publications
0
8
0
Order By: Relevance
“…We compare experimental results of depolarization samples, including microsphere suspensions and multiple biological tissues processed by the EMDI, DI, and DOPU using the catheter-based PS-OCT system. The experimental configuration of the catheter-based PS-OCT system has been previously described as depicted in Figure . Our experimental setup utilizes the depth multiplexing method based on a polarization-maintaining fiber (PMF).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…We compare experimental results of depolarization samples, including microsphere suspensions and multiple biological tissues processed by the EMDI, DI, and DOPU using the catheter-based PS-OCT system. The experimental configuration of the catheter-based PS-OCT system has been previously described as depicted in Figure . Our experimental setup utilizes the depth multiplexing method based on a polarization-maintaining fiber (PMF).…”
Section: Methodsmentioning
confidence: 99%
“…25,34 We use SMM and MMA methods to demodulate the simulation data to obtain the spatial PS-OCT image. 25,28,34 ROR are selected as 2560 pixels on the top area, and reference points for SMM and MMA are selected as a horizontal 1-pixel-width line with 512 pixels on the simulating tissue surface. 25 We calculate EMDI, DI, and DOPU based on simulation images under different g and SNR values, and then these results contrast by setting true DI and DOPU shown in Figure 2(a) shows that DOPU, DI, and EMDI for a nondepolarized simulation material with g = 1 among additive noise from SNR = 0 to 15.…”
Section: Monte Carlo Simulationmentioning
confidence: 99%
See 2 more Smart Citations
“…Considering the literature, to our knowledge, there is a gap in the studies regarding the LED NIR light beam patterns within the soft tissue. A number of the reported studies in this subject have focused on the beam patterns of the light in the fluorescence wavelengths region and in other areas of applications including the treatment of skin and mucosal diseases and Optical Coherent Tomography [25,[43][44][45][46][47][48][49][50][51][52].…”
Section: Introductionmentioning
confidence: 99%