2022
DOI: 10.3390/jcm11154463
|View full text |Cite
|
Sign up to set email alerts
|

Catheter-Associated Urinary Infections and Consequences of Using Coated versus Non-Coated Urethral Catheters—Outcomes of a Systematic Review and Meta-Analysis of Randomized Trials

Abstract: Coated urethral catheters were introduced in clinical practice to reduce the risk of catheter-acquired urinary tract infection (CAUTI). We aimed to systematically review the incidence of CAUTI and adverse effects in randomized clinical trials of patients requiring indwelling bladder catheterization by comparing coated vs. non-coated catheters. This review was performed according to the 2020 PRISMA framework. The incidence of CAUTI and catheter-related adverse events was evaluated using the Cochran–Mantel–Haens… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 31 publications
(73 reference statements)
0
5
0
Order By: Relevance
“…Overall, there was no significant difference in the CAUTI rate between silver-coated and noncoated catheters. However, the CAUTI risk was lower in the coated group among patients requiring catheterization for longer than 14 days . A coating comprised a palladium, gold, and silver alloy layer and a hydrogel outer layer significantly decreases the incidence of CAUTI .…”
Section: Resultsmentioning
confidence: 91%
See 1 more Smart Citation
“…Overall, there was no significant difference in the CAUTI rate between silver-coated and noncoated catheters. However, the CAUTI risk was lower in the coated group among patients requiring catheterization for longer than 14 days . A coating comprised a palladium, gold, and silver alloy layer and a hydrogel outer layer significantly decreases the incidence of CAUTI .…”
Section: Resultsmentioning
confidence: 91%
“…However, the CAUTI risk was lower in the coated group among patients requiring catheterization for longer than 14 days. 69 A coating comprised a palladium, gold, and silver alloy layer and a hydrogel outer layer significantly decreases the incidence of CAUTI. 70 An interesting study reported leaching of metals into urine was minimal or undetectable.…”
Section: Antimicrobial Tests Minimum Inhibitory Concentration (Mic) A...mentioning
confidence: 99%
“…These outcomes can be justified by several factors. First, the removal of debris enhances intraoperative visibility, mitigating the "snow-globe effect" and facilitating the identification of fragments hidden beneath it [32]. Moreover, this accessory obviates the need for fragment extraction, a time-consuming process impractical for fragments smaller than 2 mm [33].…”
Section: Role Of Suction In Endourology and Rirsmentioning
confidence: 99%
“…Meta‐analysis of coated versus non‐coated catheters has shown no significant differences in the incidence of CAUTI between the two categories. Still, they have highlighted the importance of outweighing the direct cost of new technologies with the potential benefit to reduce CAUTI mostly for long‐term catheterization 178 . The question remains whether it is the lack of antimicrobial technologies or the effect of the conditioning film that is limiting the ability of these technologies to adequately yield antimicrobial efficacy when compared to uncoated catheters.…”
Section: The Likely Clinical Impact Of Emerging Approachesmentioning
confidence: 99%