2021
DOI: 10.3390/photonics8100432
|View full text |Cite
|
Sign up to set email alerts
|

Case Study on the Fitting Method of Typical Objects

Abstract: This study proposes different fitting methods for different types of targets in the 400–900 nm wavelength range, based on convex optimization algorithms, to achieve the effect of high-precision spectral reconstruction for small space-borne spectrometers. This article first expounds on the mathematical model in the imaging process of the small spectrometer and discretizes it into an AX = B matrix equation. Second, the design basis of the filter transmittance curve is explained. Furthermore, a convex optimizatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…(5) (10) (15) In future research, we will investigate aspects such as dictionary and observation matching problems, and conduct imaging & spectral reconstruction experiments for imaging spectrometers using broad-bandpass filter line arrays.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…(5) (10) (15) In future research, we will investigate aspects such as dictionary and observation matching problems, and conduct imaging & spectral reconstruction experiments for imaging spectrometers using broad-bandpass filter line arrays.…”
Section: Discussionmentioning
confidence: 99%
“…20 film filters were designed and selected during the preliminary study [15], and different target spectra were input into the current simulation system for reconstruction testing. The system response can be obtained according to the quantum efficiency curves of the detector and the optical response of filters.…”
Section: Simulation and Analysismentioning
confidence: 99%
“…The target spectrum X( ) λ passes through the filter array at the front of the detector W( ) λ . The gray value B [10][11][12] is obtained after modulation of the quantum efficiency G( )…”
Section: Spectrometermentioning
confidence: 99%
“…The obtained lifetime values are 93, 76, and 27 μs for 3, 5, and 7 mol% Er 3+ ions in the SnO 2 host, respectively. It is noticed that the lifetime values are found to be much higher than that of Er 3+ -doped TeO 2 -ZnO glasses [61] and comparable to Er 3+ -doped LuGG crystal [62] and Er 3+ /Yb 3+ -doped La 2 O 2 S [42]. The lifetime values are observed to be decreasing with increasing Er 3+ concentration due to concentration quenching [63].…”
Section: Decay Curves Of Red Upconversion Emissionmentioning
confidence: 99%