2019
DOI: 10.1109/tpel.2019.2907652
|View full text |Cite
|
Sign up to set email alerts
|

Cascaded Proportional Control With Algebraic Estimators for PFC AC/DC Converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 24 publications
(5 citation statements)
references
References 38 publications
0
5
0
Order By: Relevance
“…Some methods were proposed to combine reduction of current distortion with responsiveness of DC voltage control by feedforward of load current, 16 exclusion of ripple voltage components calculated from input current, 17 or removal of ripple from detected DC voltage using a notch filter. 18 Particularly, assuming control using analog IC, complex calculations must be avoided in terms of circuit size limitations. Besides, regarding limitations on monolithic capacitance in IC, circuits with a time constant at the commercial frequency level are realized externally.…”
Section: Forewordmentioning
confidence: 99%
“…Some methods were proposed to combine reduction of current distortion with responsiveness of DC voltage control by feedforward of load current, 16 exclusion of ripple voltage components calculated from input current, 17 or removal of ripple from detected DC voltage using a notch filter. 18 Particularly, assuming control using analog IC, complex calculations must be avoided in terms of circuit size limitations. Besides, regarding limitations on monolithic capacitance in IC, circuits with a time constant at the commercial frequency level are realized externally.…”
Section: Forewordmentioning
confidence: 99%
“…Besides, the delay-average module in voltage control system is intended to reduce current distortion caused by DC voltage ripple. [11][12][13][14] Details are given in Appendix.…”
Section: Configuration Of Control Systemmentioning
confidence: 99%
“…In a single-phase AC/DC conversion circuit, DC ripple component at the double input frequency is superimposed on amplitude reference in input current control, thus causing distortion; a number of methods were proposed to suppress this distortion. [11][12][13][14] In this study, the ripple component is canceled by adding a value stored ¼ input period (that is, ripple half-period) before.…”
Section: Principle Of Delay Averaging and Stability Analysismentioning
confidence: 99%
“…In addition, it can improve the closed‐loop performance when controlling plants with non‐minimum‐phase (NMP) zeros [2, 3] or time delays [4, 5]. In terms of practical applications, we can point out several recent works in the field of power electronics [6–9], unmanned aerial vehicles [5, 10, 11] and process control [12, 13].…”
Section: Introductionmentioning
confidence: 99%
“…Design methods for cascade control are in general model‐based, ranging from robust state‐feedback [14] to frequency‐response methods [6]. The plant multi‐loop nature may impose difficulties to the modelling and/or system identification task, most notable the requirement of several plant experiments and coupling between inner and outer loops [1, 15].…”
Section: Introductionmentioning
confidence: 99%