2017
DOI: 10.1016/j.sna.2017.09.038
|View full text |Cite
|
Sign up to set email alerts
|

Cascaded distributed multichannel fiber SPR sensor based on gold film thickness adjustment approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 38 publications
(15 citation statements)
references
References 23 publications
1
14
0
Order By: Relevance
“…In an SPR-based fiber optic sensor, because all the guided rays are launched, the detector obtains the accumulation of all transmission modes corresponding to each angle. Figure 2 b shows normalized spectrums of the sensor in different RIs; the sensor shows a clear resonance which shifts towards the red wavelength range when the RI increases in the surrounding liquid, which is consistent with the reported SPR sensors based on Au coatings [ 17 ]. We changed the liquid RIs by using different sodium chloride solutions which were calibrated by an Abbe refractometer (WAY-2S).…”
Section: Methodssupporting
confidence: 86%
“…In an SPR-based fiber optic sensor, because all the guided rays are launched, the detector obtains the accumulation of all transmission modes corresponding to each angle. Figure 2 b shows normalized spectrums of the sensor in different RIs; the sensor shows a clear resonance which shifts towards the red wavelength range when the RI increases in the surrounding liquid, which is consistent with the reported SPR sensors based on Au coatings [ 17 ]. We changed the liquid RIs by using different sodium chloride solutions which were calibrated by an Abbe refractometer (WAY-2S).…”
Section: Methodssupporting
confidence: 86%
“…It is necessary to plate a 300 nm gold film as the reflected film on the inclined plane of the step-index multi-mode fiber with the same grinding angle. According to the research of Zhang et al (2017), the most suitable thickness of the sensing gold film is 50 nm. Besides, the sensing effects are also affected by metal nanoparticles.…”
Section: Design Of the Sensor Structure And Theoretical Modelingmentioning
confidence: 99%
“…The sensitivities of the two channels are 1712 and 3038 nm RIU −1 , respectively. [80] Particularly worth mentioning is that when the two channels are working at the same time, the sensitivity and the moving range of each channel remain unchanged, which shows that the two sensing channels independently respond to the analytes to be measured.…”
Section: Changing the Thickness Of The Metal Layermentioning