VIII IEEE International Power Electronics Congress, 2002. Technical Proceedings. CIEP 2002.
DOI: 10.1109/ciep.2002.1216655
|View full text |Cite
|
Sign up to set email alerts
|

Cascade multilevel inverter with only one DC source

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
12
0

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 9 publications
0
12
0
Order By: Relevance
“…The cascade inverter topology has been main area of research for the shunt compensator applications in the transmission system [7]- [12]. In the shunt compensator applications, a transformer is necessary to connect the cascade inverter structure to the transmission or distribution systems, once a single dc-link capacitor is used for all the three phases [9]. For distribution systems, the transformer may not be required in some cases as the multilevel inverter itself may be capable of achieving the desired voltage level.…”
Section: Introductionmentioning
confidence: 99%
“…The cascade inverter topology has been main area of research for the shunt compensator applications in the transmission system [7]- [12]. In the shunt compensator applications, a transformer is necessary to connect the cascade inverter structure to the transmission or distribution systems, once a single dc-link capacitor is used for all the three phases [9]. For distribution systems, the transformer may not be required in some cases as the multilevel inverter itself may be capable of achieving the desired voltage level.…”
Section: Introductionmentioning
confidence: 99%
“…Recently cascaded transformer multilevel topology is proposed [9,10]. This has the advantage of having single DC source for all its cells.…”
Section: Introductionmentioning
confidence: 99%
“…Novel topologies of multilevel inverters using a reduced number of switches, gate driver circuits and DC sources are presented in recent years [7][8][9][10]. In [7] and [8] novel configuration of multilevel inverters have been proposed.…”
Section: Introductionmentioning
confidence: 99%
“…However, the cascaded H-bridge type multilevel inverter has a disadvantage that the independent DC-link voltage needs to be provided by each H-bridge separately. To reduce the number of independent DC sources, methods were introduced in recent years [15].…”
Section: Introductionmentioning