2015
DOI: 10.1016/j.jcrc.2015.08.014
|View full text |Cite
|
Sign up to set email alerts
|

Carotid artery corrected flow time measurement via bedside ultrasonography in monitoring volume status

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
43
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 48 publications
(46 citation statements)
references
References 24 publications
1
43
2
Order By: Relevance
“…CFT is the carotid systole time, with heart rate correction applied. This measure is easy to perform and may correlate with intravascular volume [22]. CBF is the integral of blood volume that is ejected through the carotid artery with each cardiac cycle.…”
Section: Introductionmentioning
confidence: 99%
“…CFT is the carotid systole time, with heart rate correction applied. This measure is easy to perform and may correlate with intravascular volume [22]. CBF is the integral of blood volume that is ejected through the carotid artery with each cardiac cycle.…”
Section: Introductionmentioning
confidence: 99%
“…Blehar et al [84] also indicated that after fluid administration, although there was a significant change in FTc, there were no changes in mean arterial pressure or heart rate emphasizing the value of using FTc. Although Mackenzie et al [85] studied on blood donors, Hossein-Nejad et al [27] included hemodialysis patients in their study and both studies found a significant relationship showing decreased FTc in response to loss of intravascular volume. Hossein-Nejad et al [27] also indicated that decrease in FTc was significant in both groups of patients with or without a history of anti-hypertensive drug use.…”
Section: Carotid Artery -Corrected Flow Timementioning
confidence: 98%
“…Although Mackenzie et al [85] studied on blood donors, Hossein-Nejad et al [27] included hemodialysis patients in their study and both studies found a significant relationship showing decreased FTc in response to loss of intravascular volume. Hossein-Nejad et al [27] also indicated that decrease in FTc was significant in both groups of patients with or without a history of anti-hypertensive drug use. A study done by Stolz et al [88] to investigate the applicability of Doppler to measure common CA velocity time integral, which is a novel another method for potential use in assessing volume responsiveness, was performed in emergency settings by emergency residents from a single institution to assess volume status.…”
Section: Carotid Artery -Corrected Flow Timementioning
confidence: 98%
See 2 more Smart Citations