2005
DOI: 10.1053/j.semnuclmed.2004.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Cardiac positron emission tomography imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
117
0
14

Year Published

2006
2006
2017
2017

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 156 publications
(131 citation statements)
references
References 114 publications
0
117
0
14
Order By: Relevance
“…Validation of the use of 82 Rb/PET myocardial perfusion imaging to study cardiovascular function related to blockage of the coronary artery has been previously reported [42,43]. In spite of the relatively short physical half-life of 82 Rb, the PET imaging studies were successful and showed comparable or improved detection of myocardial perfusion in patients with coronary artery diseases [44][45][46]. The convenience of using a generator system for routine imaging has fueled the expansion of PET imaging application in nuclear cardiology.…”
Section: Autoradiography In Normal and Infarct Rat Heart Modelsmentioning
confidence: 99%
“…Validation of the use of 82 Rb/PET myocardial perfusion imaging to study cardiovascular function related to blockage of the coronary artery has been previously reported [42,43]. In spite of the relatively short physical half-life of 82 Rb, the PET imaging studies were successful and showed comparable or improved detection of myocardial perfusion in patients with coronary artery diseases [44][45][46]. The convenience of using a generator system for routine imaging has fueled the expansion of PET imaging application in nuclear cardiology.…”
Section: Autoradiography In Normal and Infarct Rat Heart Modelsmentioning
confidence: 99%
“…Il est actuellement disponible aux USA dans 2 sociétés (Bristol Myers Squibb et Eastern Isotopes) à un coût encore excessif. La spécificité du rubidium-82 a été démontrée supérieure à celle du thallium et du technétium du fait de la correction d'atténuation plus efficace avec un émetteur de photons de 511 keV (Machac, 2005). Sa courte période physique permet d'injecter de fortes activités (1,85 GBq) au malade et de répéter l'examen 10 minutes plus tard pour des épreuves pharmacologiques.…”
Section: (B) Radionucléides éMetteurs De Positonsunclassified
“…When compared with the gold standard of invasive coronary angiography, cardiac PET, using 31N ammonia and 18 RB, has demonstrated an overall sensitivity of 93% and specificity of 92% when diagnosing coronary artery disease. 37 In comparison to SPECT, Go and colleagues showed a 95% sensitivity and 82% specificity for 82RB PET compared to a 79% and 76% respectively for SPECT. 38 In assessing myocardial viability, the intent is to determine whether areas of poorly perfused myocardium are still alive and hence may benefit from revascularization.…”
Section: Pet In Cardiologymentioning
confidence: 99%