2010
DOI: 10.1186/1475-925x-9-80
|View full text |Cite
|
Sign up to set email alerts
|

Cardiac output estimation using pulmonary mechanics in mechanically ventilated patients

Abstract: The application of positive end expiratory pressure (PEEP) in mechanically ventilated (MV) patients with acute respiratory distress syndrome (ARDS) decreases cardiac output (CO). Accurate measurement of CO is highly invasive and is not ideal for all MV critically ill patients. However, the link between the PEEP used in MV, and CO provides an opportunity to assess CO via MV therapy and other existing measurements, creating a CO measure without further invasiveness.This paper examines combining models of diffusi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2011
2011
2012
2012

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 31 publications
0
2
0
Order By: Relevance
“…In the critical care arena, the use of in silico physiological models is only emerging. However, there are already model-based or model-derived applications for managing sedation [ 25 , 26 ], cardiovascular diagnosis and therapy [ 27 , 28 ], mechanical ventilation [ 29 , 30 ], and the diagnosis of sepsis [ 31 , 32 ]. Particular to TGC, there are already some attempts at modeling for both understanding and implementing TGC [ 23 , 33 - 42 ], with a review of many in [ 43 ].…”
Section: A Series Of Questionsmentioning
confidence: 99%
“…In the critical care arena, the use of in silico physiological models is only emerging. However, there are already model-based or model-derived applications for managing sedation [ 25 , 26 ], cardiovascular diagnosis and therapy [ 27 , 28 ], mechanical ventilation [ 29 , 30 ], and the diagnosis of sepsis [ 31 , 32 ]. Particular to TGC, there are already some attempts at modeling for both understanding and implementing TGC [ 23 , 33 - 42 ], with a review of many in [ 43 ].…”
Section: A Series Of Questionsmentioning
confidence: 99%
“…It should be emphasized that non-invasive methods of CO measurements are recognized as less accurate [2,3,6,8] and minimally invasive methods must be calibrated before examination by means of thermodilution [7,8]. Actually there are a few methods based on other physical principles [9,10], but nowadays they are being developed. The PAC technique by means of the Swan-Ganz catheter allows to obtain or calculate other valuable hemodynamic parameters basing on intracardiac pressures, e.g.…”
Section: Introductionmentioning